• J Intensive Care Med · Mar 2011

    Comparative Study Clinical Trial

    Inferior vena cava variation compared to pulse contour analysis as predictors of fluid responsiveness: a prospective cohort study.

    • Enrique Machare-Delgado, Matthew Decaro, and Paul E Marik.
    • Division of Pulmonary and Critical Care Medicine, Thomas Jefferson University, Philadelphia, PA, USA.
    • J Intensive Care Med. 2011 Mar 1;26(2):116-24.

    BackgroundBoth occult hypoperfusion and volume overload are associated with increased morbidity and mortality in critically ill patients. Accurately predicting fluid responsiveness (FRes) allows for optimization of cardiac performance while avoiding fluid overload and prolonged mechanical ventilation.ObjectiveTo simultaneously assess the ability to predict FRes using the stroke volume variation (SVV) obtained with the Vigileo/Flotrac monitor and inferior vena cava respiratory variation (ΔIVC) measured by standard echocardiography ([ECHO) during mechanical ventilation.MethodsWe included medical intensive care unit (ICU) patients undergoing mechanical ventilation that required vasopressors, had worsening organ function, and that were well adapted to the ventilator. We excluded patients requiring escalating doses of vasopressors, hemodialysis, with ascites and patients with atrial fibrillation or a heart rate >120/min. Stroke volume index (SVI) and SVV were obtained from the Vigileo monitor whereas ΔIVC was obtained with ECHO (M-mode). Doppler ECHO was used to measure SVI and used to determine FRes (defined by SVI increase ≥ 10%). A data set was obtained before and 30 minutes after a 10-minute fluid challenge (FC) with 500 mL of saline.ResultsIn all, 25 patients were prospectively enrolled over an 8-month period. A total of 12 patients had acute respiratory distress syndrome (ARDS), 3 had a cardiac arrest, and 10 had sepsis. The patients' mean age was 61.36 years (±13.7), study enrollment since ICU admission was 3.4 days (±3.39), the Sequential Organ Failure Assessment (SOFA) score was 12.44 (±2.59), and the tidal volume 8.6 mL/kg (±1.68). Of the 25 patients, 8 (32%) were FRes. The correlation coefficient between the baseline ΔIVC and percentage increase in SVI (by ECHO) after an FC was R(2) = .51 with a receiver operating characteristic (ROC) curve of 0.81 while that for the baseline SVV by Vigileo was R(2) = .12 with an ROC curve of 0.57. The mean SVI bias between ECHO and Vigileo was -2 mL/m(2), the precision was -18 to 14 and the mean error was 46%.ConclusionsECHO assessment of the IVC variation during mechanical ventilation may prove to be a useful technique to predict FRes and guide fluid resuscitation in the ICU. The SVV obtained with the Vigileo monitor failed to predict FRes likely due to lack of calibration and the use of a complex algorithm that may be unreliable in patients with sepsis.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…