• J Spinal Disord Tech · Oct 2008

    Clinical Trial

    C2 pedicle screw and plate combined with C1 titanium cable fixation for the treatment of atlantoaxial instability not suitable for placement of C1 screw.

    • Zeng Ming Xiao, Xin Li Zhan, De Feng Gong, Qian Fen Chen, Gao Bin Luo, and Hua Jiang.
    • Department of Orthopaedics, The First Affiliated Hospital of Guang Xi Medical University, Nanning, China.
    • J Spinal Disord Tech. 2008 Oct 1;21(7):514-7.

    Study DesignA method of atlantoaxial stabilization using individual fixation of the C1 posterior arch and the C2 pedicle with C2 pedicle screws and plates combined with C1 titanium cables is described. In addition, the clinical results of this method on 8 patients are described.ObjectiveTo describe the method and the clinical and radiographic results for posterior C1-C2 fixation with a combined implant system.Summary Of Background DataStabilization of the atlantoaxial complex is a challenging procedure because of the unique anatomy of this region. Fixation by plate or rod and C1 and C2 screw and structural bone grafting leads to excellent fusion rates. The technique is technically demanding and has a potential risk of the injuries to the vertebral artery, the internal carotid artery, spinal cord, and hypoglossal nerves. In addition, how to stabilize the atlantoaxial complex in the cases not suitable for placement of C1 screw is not described in the literature. To address these limitations, a method of C1-C2 fixation has been developed: bilateral insertion of C2 pedicle screws and rolling of C1 titanium cable through the posterior arch of atlas and the cranial hole of the plate, followed by C1-C2 plate fixation.MethodsFrom February 2003 to March 2006, 8 patients with atlantoaxial instability and not suitable for placement of C1 screw were included in this study: 5 cases of broken C1 pedicle screw trajectory and 3 cases of C1 anatomic anomalies. Skull traction was performed in each patient preoperatively. The pedicle screws were inserted into C2 pedicles in the direction as its axis. C1 titanium cable was rolled superior to lower through posterior arch of atlas in the cases not suitable for placement of C1 screw. The C1-C2 plate was slightly bent to fit the upper cervical contour. Hyperflexion alignment of the atlantoaxial complex was corrected by application of extension force created by tightening of the nut on the pedicle screws and the C1 titanium cable, which was passed through the cranial hole of the plate. Morselized autogenous cancellous iliac grafts were placed on the surface of the posterior arches of both atlas and axis. All patients were assessed clinically for neurologic recovery by Odom's method.ResultsThere were 5 males and 3 females with a mean age of 37.8 years (range, 17 to 59 y). There were 2 cases of old odontoid fracture, 2 cases fresh odontoid fracture (Aderson II C), 2 cases atlas transverse ligament laxation, 2 cases atlas transverse ligament rupture, and in these cases, 5 cases had failed placement of C1 screw because of broken C1 pedicle screw trajectory and 3 cases not suitable for placement of C1 screw because of anatomic anomalies. There were no spinal cord and vertebral artery and nerve injury after surgery. Follow-up duration was from 18 to 55 months with the average of 29 months. The plant bones all fused and there were no internal fixation rupture and mobility. All the patients showed improvement.ConclusionsC2 pedicle screw and plate combined with C1 titanium cable could be used to treat atlantoaxial instability in the cases not suitable for placement of C1 screw.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.