• Journal of neurosurgery · Mar 2011

    Case Reports

    Intraoperative magnetic resonance imaging-guided tractography with integrated monopolar subcortical functional mapping for resection of brain tumors. Clinical article.

    • Sujit S Prabhu, Jaime Gasco, Sudhakar Tummala, Jefrey S Weinberg, and Ganesh Rao.
    • Department of Neurosurgery, University of Texas M. D. Anderson Cancer Center, Houston, Texas, USA. sprabhu@mdanderson.org
    • J. Neurosurg. 2011 Mar 1;114(3):719-26.

    ObjectThe object of this study was to describe the utility and safety of using a single probe for combined intraoperative navigation and subcortical mapping in an intraoperative MR (iMR) imaging environment during brain tumor resection.MethodsThe authors retrospectively reviewed those patients who underwent resection in the iMR imaging environment, as well as functional electrophysiological monitoring with continuous motor evoked potential (MEP) and direct subcortical mapping combined with diffusion tensor imaging tractography. RESULTS As a navigational tool the monopolar probe used was safe and accurate. Positive subcortical fiber MEPs were obtained in 10 (83%) of the 12 cases. In 10 patients in whom subcortical MEPs were recorded, the mean stimulus intensity was 10.4 ± 5.2 mA and the mean distance from the probe tip to the corticospinal tract (CST) was 7.4 ± 4.5 mm. There was a trend toward worsening neurological deficits if the distance to the CST was short, and a small minimum stimulation threshold was recorded indicating close proximity of the CST to the resection margins. Gross-total resection (95%-100% tumor removal) was achieved in 11 cases (92%), whereas 1 patient (8%) had at least a 90% tumor resection. At the end of 3 months, 2 patients (17%) had persistent neurological deficits.ConclusionsThe monopolar probe can be safely implemented in an iMR imaging environment both for navigation and stimulation purposes during the resection of intrinsic brain tumors. In this study there was a trend toward worsening neurological deficits if the distance from the probe to the CST was short (< 5 mm) indicating close proximity of the resection cavity to the CST. This technology can be used in the iMR imaging environment as a surgical adjunct to minimize adverse neurological outcomes.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…