• Spine J · Dec 2010

    Review

    Dural repair with four spinal sealants: focused review of the manufacturers' inserts and the current literature.

    • Nancy E Epstein.
    • The Leo M. Davidoff Department of Neurological Surgery, The Albert Einstein College of Medicine, Bronx 10461, NY, USA. dch3@columbia.edu
    • Spine J. 2010 Dec 1;10(12):1065-8.

    Background ContextDeliberate or traumatic dural fistulas are typically augmented by a "sealant" or "fibrin glue" to enhance the strength of dural closure.PurposeLittle is known about the risks and complications associated with two specific "sealants" and two specific "fibrin glues" used for dural closure.Study Design/SettingReview of the manufacturers' inserts and a focused review of the literature concerning the pros and cons for two "sealants" (DuraSeal [Confluent Surgical Inc., Waltham, MA, USA] and BioGlue [Cryolife, Kennesaw, GA, USA]) and two "fibrin glues" (EVICEL [Johnson and Johnson Wound Management, Ethicon Inc., Somerville, NJ, USA] and Tisseel [fibrin sealant; Baxter International Inc., Westlake Village, CA, USA]) were assessed.Patient SampleA focused review of the literature using four different "sealants" or "fibrin glues" was performed.Outcome MeasuresDocumentation of persistent/recurrent postoperative cerebrospinal fluid fistulas was an end point for failure for the four different "sealants" and "fibrin glues."MethodsManufacturers' inserts and a focused review of the literature concerning the relative safety and efficacy of two "sealants" (DuraSeal and BioGlue) and two "fibrin glues" (EVICEL and Tisseel) used to augment dural closure were assessed.ResultsAlthough DuraSeal is approved by the Federal Drug Administration (FDA) for intracranial and spinal application, two instances of paralysis are described in the literature. BioGlue is classified by the manufacturer as neurotoxic. EVICEL, one of the "fibrin glues," appeared in just two animal studies, whereas Tisseel, the other "fibrin glue," has been used in many large clinical series without adverse events.ConclusionDespite the lack of FDA approval, Tisseel (fibrin glue) has seen wide adoption in "off-label" use. DuraSeal, which is FDA approved, was associated with two instances of paralysis. Alternatively, BioGlue was described as neurotoxic even by the manufacturer.Copyright © 2010 Elsevier Inc. All rights reserved.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.