-
Acta neurochirurgica · Jun 2010
Flow replacement bypass for aneurysms: decision-making using intraoperative blood flow measurements.
- Sepideh Amin-Hanjani, Ali Alaraj, and Fady T Charbel.
- Department of Neurosurgery, Neuropsychiatric Institute (MC 799), University of Illinois at Chicago, 912 South Wood Street, Chicago, IL 60612, USA. hanjani@uic.edu
- Acta Neurochir (Wien). 2010 Jun 1;152(6):1021-32; discussion 1032.
PurposeThere is much debate regarding the optimal strategy for extracranial-intracranial (EC-IC) bypass for complex aneurysms. We introduce the concept of a flow replacement bypass which aims to compensate for loss of flow in the efferent vessels of the aneurysm. The strategy to achieve this utilizes direct intraoperative flow measurements to guide optimal revascularization by matching graft flow to demand.MethodsWe reviewed all EC-IC bypass cases performed over a 6-year period. We identified cases in which intraoperative flow measurements using an ultrasonic flow probe were utilized to determine the revascularization strategy and analyzed the decision-making paradigm.ResultsTwenty-three cases were analyzed. For terminal aneurysms, flow measurement in the affected vessel at baseline predicted the flow required for full replacement: middle cerebral artery (MCA), 50 +/- 25 cc/min (n = 9); posterior inferior cerebellar artery (PICA), 13 +/- 7 cc/min (n = 4); posterior cerebral artery (PCA), 33 cc/min (n = 1); and superior cerebellar artery (SCA), 10 cc/min (n = 1). For proximal internal carotid artery (ICA) aneurysms (n = 8), the flow deficit from baseline during carotid temporary occlusion was measured (26 +/- 18 cc/min, an average of 44% drop from baseline). The adequacy of flow from the superficial temporal artery (STA) or occipital artery (OA), when available, was assessed prior to bypass, and STA, OA, or vein interposition grafts were used accordingly. Measurement of bypass flow following anastomosis confirmed not only patency but sufficient flow in all cases: MCA 50 +/- 25 cc/min, PICA 18 +/- 9 cc/min, PCA 64 cc/min, SCA 12 cc/min, ICA 36 +/- 25 cc/min (STA), and >200 cc/min (vein).ConclusionsDirect intraoperative measurement of flow deficit in aneurysm surgery requiring parent vessel sacrifice can guide the choice of flow replacement graft and confirm the subsequent adequacy of bypass flow.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.