Influences of cannula size and flow rate on aerosol drug delivery through the Vapotherm humidified high-flow nasal cannula system.
- Sarah A Perry, Kenneth C Kesser, David E Geller, Dawn M Selhorst, John K Rendle, and James H Hertzog.
- Department of Anesthesiology and Critical Care Medicine, Nemours/Alfred I. duPont Hospital for Children, Wilmington, DE, USA.
- Pediatr Crit Care Me. 2013 Jun 1;14(5):e250-6.
ObjectiveWe investigated the in vitro inspired dose and particle size distribution of albuterol delivered by a vibrating mesh nebulizer through the Vapotherm (Stevensville, MD) humidified high-flow nasal cannula system.DesignAlbuterol (2.5 mg/3 mL) was delivered by an Aeroneb Solo (Aerogen, Galway, Ireland) nebulizer that was connected via adaptor proximal to the nasal cannula and downstream from the Vapotherm 2000i. Albuterol was collected onto an inspiratory filter mounted to a breath simulator programmed with age-appropriate breathing patterns. Particle sizing was completed by cascade impaction. Albuterol was quantified using ultraviolet spectrometry. Measurements were made using varying flow rates through infant, pediatric, and adult nasal cannulae.SettingAerosol research laboratory.Measurements And Main ResultsThe inspired dose (percent of nominal dose) for each cannula size and flow rate was 2.5%, 0.8%, 0.4%, and 0.2% for the adult cannula at 5, 10, 20, and 40 L/min, respectively; 1.2%, 0.6%, 0.1%, and 0.0% for the pediatric cannula at 3, 5, 10, and 20 L/min, respectively; and 0.6%, 0.6%, and 0.5% for the infant cannula at 3, 5, and 8 L/min, respectively. Most (62-80%) of the loaded albuterol dose accumulated within the adaptor. For each cannula size, there was a significant decrease in the inspired dose with increasing flow rates, p = 0.026 (infant), p = 0.001 (pediatric), and p < 0.001(adult). The inspired dose increased with increasing cannula size for 5, 10, and 20 L/min (p = 0.007, p < 0.001, and p = 0.005, respectively). The mass median aerodynamic diameter for all trials was less than 5 µm.ConclusionThe amount of albuterol delivered with the Vapotherm system using this model was lower than the amount expected for a clinical response for the majority of flow rates and cannula size combinations. Further studies are needed before routine use of aerosolized albuterol through a Vapotherm high-flow system can be recommended.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.