• N. Engl. J. Med. · Feb 2016

    Multicenter Study Clinical Trial

    A Leadless Intracardiac Transcatheter Pacing System.

    • Dwight Reynolds, Gabor Z Duray, Razali Omar, Kyoko Soejima, Petr Neuzil, Shu Zhang, Calambur Narasimhan, Clemens Steinwender, Josep Brugada, Michael Lloyd, Paul R Roberts, Venkata Sagi, John Hummel, Maria Grazia Bongiorni, Reinoud E Knops, Christopher R Ellis, Charles C Gornick, Matthew A Bernabei, Verla Laager, Kurt Stromberg, Eric R Williams, J Harrison Hudnall, Philippe Ritter, and Micra Transcatheter Pacing Study Group.
    • From the Cardiovascular Section, University of Oklahoma Health Sciences Center, OU Medical Center, Oklahoma City (D.R.); Clinical Electrophysiology Department of Cardiology, Medical Center, Hungarian Defence Forces, Budapest, Hungary (G.Z.D.); Electrophysiology and Pacing Unit, National Heart Institute, Kuala Lumpur, Malaysia (R.O.); Department of Cardiology, Kyorin University Hospital, Tokyo (K. Soejima); Department of Cardiology, Na Homolce Hospital, Prague, Czech Republic (P.N.); Clinical EP Lab and Arrhythmia Center, Fuwai Hospital, Beijing (S.Z.); Division of Electrophysiology, Department of Cardiology, CARE Hospitals and CARE Foundation, Hyderabad, India (C.N.); Department of Cardiology, Linz General Hospital, Johannes Kepler University School of Medicine, Linz, Austria (C.S.); Hospital Universitari Clínic de Barcelona, Barcelona (J.B.); Emory University Hospital, Atlanta (M.L.); University of Southampton, Southampton, United Kingdom (P.R.R.); Baptist Heart Specialists, Jacksonville, FL (V.S.); Ohio State University, Columbus (J.H.); Azienda Ospedaliero Universitaria Pisana, Presidio Ospedaliero di Cisanello, Pisa, Italy (M.G.B.); Academisch Medisch Centrum, Amsterdam (R.E.K.); Vanderbilt University Medical Center, Nashville (C.R.E.); Minneapolis Heart Institute, Minneapolis (C.C.G.); Lancaster Heart and Vascular Institute, Lancaster, PA (M.A.B.); Medtronic, Mounds View, MN (V.L., K. Stromberg, E.R.W., J.H.H.); and Hôpital Cardiologique du Haut-Lévêque, Centre Hospitalier Universitaire Bordeaux, Université Bordeaux, IHU l'Institut de Rythmologie et Modélisation Cardiaque, Bordeaux, France (P.R.).
    • N. Engl. J. Med. 2016 Feb 11;374(6):533-41.

    BackgroundA leadless intracardiac transcatheter pacing system has been designed to avoid the need for a pacemaker pocket and transvenous lead.MethodsIn a prospective multicenter study without controls, a transcatheter pacemaker was implanted in patients who had guideline-based indications for ventricular pacing. The analysis of the primary end points began when 300 patients reached 6 months of follow-up. The primary safety end point was freedom from system-related or procedure-related major complications. The primary efficacy end point was the percentage of patients with low and stable pacing capture thresholds at 6 months (≤2.0 V at a pulse width of 0.24 msec and an increase of ≤1.5 V from the time of implantation). The safety and efficacy end points were evaluated against performance goals (based on historical data) of 83% and 80%, respectively. We also performed a post hoc analysis in which the rates of major complications were compared with those in a control cohort of 2667 patients with transvenous pacemakers from six previously published studies.ResultsThe device was successfully implanted in 719 of 725 patients (99.2%). The Kaplan-Meier estimate of the rate of the primary safety end point was 96.0% (95% confidence interval [CI], 93.9 to 97.3; P<0.001 for the comparison with the safety performance goal of 83%); there were 28 major complications in 25 of 725 patients, and no dislodgements. The rate of the primary efficacy end point was 98.3% (95% CI, 96.1 to 99.5; P<0.001 for the comparison with the efficacy performance goal of 80%) among 292 of 297 patients with paired 6-month data. Although there were 28 major complications in 25 patients, patients with transcatheter pacemakers had significantly fewer major complications than did the control patients (hazard ratio, 0.49; 95% CI, 0.33 to 0.75; P=0.001).ConclusionsIn this historical comparison study, the transcatheter pacemaker met the prespecified safety and efficacy goals; it had a safety profile similar to that of a transvenous system while providing low and stable pacing thresholds. (Funded by Medtronic; Micra Transcatheter Pacing Study ClinicalTrials.gov number, NCT02004873.).

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…