• Oper Orthop Traumatol · Feb 2005

    Clinical Trial

    Limb lengthening with the Intramedullary Skeletal Kinetic Distractor (ISKD).

    • Stefan Hankemeier, Thomas Gösling, Hans-Christoph Pape, Ulrich Wiebking, and Christian Krettek.
    • Unfallchirurgische Klinik, Medizinische Hochschule Hannover, Carl-Neuberg-Strasse 1, D-30625, Hannover. hankemeier.stefan@mh-hannover.de
    • Oper Orthop Traumatol. 2005 Feb 1;17(1):79-101.

    ObjectiveCallus distraction of the femur or tibia with an intramedullary distractor, which lengthens mechanically through alternating rotations of at least 3 degrees.IndicationsFemoral or tibial shortening between 20 and 80 mm. Angular and rotational deformities can be corrected at the osteotomy site.ContraindicationsOpen epiphyses. Small medullary canal (after intramedullary reaming femoral diameter < 14.5 mm, tibial diameter < 12.5 mm). Severe deformities. Insufficient compliance. Osteitis. Soft-tissue infections.Surgical TechniqueSupine position. Femoral shaft osteotomy at the proximal or middle third by multiple drill holes completed with a chisel. For lengthening of the tibia, osteotomy with a Gigli saw is preferred. Control of the rotation by two parallel 3.0-mm Kirschner wires. Correction of angular or rotational deformities. Via stab incision reaming of the medullary canal with a flexible reamer. The femur is overreamed 2.0 mm and the tibia 1.5 mm above the desired implant diameter. Insertion of the Intramedullary Skeletal Kinetic Distractor (ISKD) into the medullary canal and distal locking in freehand technique. Control of the rotation and of the osteotomy gap. Proximal locking with an aiming device. For femoral lengthening 3 days and for tibial lengthening 5 days postoperatively the distraction is begun by increasing mobilization with partial weight bearing, to achieve daily distraction of 1 mm. In case of insufficient distraction, additional rotations are performed by the patient while checking the external monitor that displays the daily and total distraction length.ResultsIntramedullary lengthening with the ISKD was performed in four patients having an average age of 29 years (18-36 years). Two femoral shortenings were combined with complex rotational and angular deformities. The average lengthening of three femora and one tibia was 31 mm (26-40 mm). The average intraoperative blood loss was 230 ml (110-320 ml), the mean surgical time 108 min (90-145 min). The average daily distraction amounted to 1.2 mm (0.9-1.8 mm). Full weight bearing was permitted after 10 weeks (7-14 weeks), return to regular work after 11 weeks (7-16 weeks). At follow-up examination of an average of 2.3 years postoperatively the knee range of motion was full. Consolidation was noted 80 days (51-111 days) postoperatively with an average consolidation index of 2.9 days/mm (1.8-4.1 days/mm). No complications were observed. According to the Paley Score all patients had an excellent outcome.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,694,794 articles already indexed!

We guarantee your privacy. Your email address will not be shared.