• J Orthop Trauma · Feb 1998

    Randomized Controlled Trial Comparative Study Clinical Trial

    Outer gloves in orthopaedic procedures: a polyester/stainless steel wire weave glove liner compared with latex.

    • S S Louis, E L Steinberg, O A Gruen, C S Bartlett, and D L Helfet.
    • Orthopaedic Trauma Service, Good Samaritan Hospital, Downers Grove, Illinois, USA.
    • J Orthop Trauma. 1998 Feb 1;12(2):101-5.

    ObjectiveTo compare the efficacy of traditional double latex gloving with that of a highly cut-resistant polyester/stainless steel wire weave glove (PSSWWG) over a single latex inner glove for the prevention of perforation of the inner latex glove.DesignThe primary surgeon and first assistant were involved in a prospective randomized study. Group I consisted of twenty-five procedures in which double latex gloves were used. Group II consisted of twenty-five procedures in which a PSSWWG liner was worn over an inner latex glove. All inner gloves were tested for perforations; all gloves exchanged that were presumed to have a perforation were noted and also tested. The type and length of the procedure were recorded. The dominant hand was recorded for all participants, along with their comments on the PSSWWG liner's performance.SettingOrthopaedic Trauma Service, Hospital for Special Surgery. New York.Patients/ParticipantsMajor operative cases, November 1996 to February 1997.Main Outcome MeasurementsInner latex glove perforations.ResultsWith the use of PSSWWG liners, the percentage of inner gloves found with a perforation dropped from 19 percent in the double latex group to 15 percent in the PSSWWG liner group (not statistically significant, p = 0.4). Two thirds of the perforations were in the primary surgeon's gloves, located in either the index finger or thumb. Nearly 80 percent of all perforations went unrecognized in both groups. Ninety-five percent of all perforations were in gloves that had been in use for more than 120 minutes (statistically significant, p = 0.01).ConclusionsThe particular cut-resistant glove studied (Sceptor) did not significantly reduce the rate of inner glove perforations. Other studies with different cut-resistant glove types and protocols have proven the liners effective. We would still recommend using outer cloth or cut-resistant type gloves when bone fragments are being manipulated or when using sharp implants or saws. At a minimum, surgical gloves should be changed every two hours.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…