- Andrew D McInnes, Robert M Sutton, Akira Nishisaki, Dana Niles, Jessica Leffelman, Lori Boyle, Matthew R Maltese, Robert A Berg, and Vinay M Nadkarni.
- The Children's Hospital of Philadelphia, Department of Anesthesia and Critical Care Medicine, 34th Street and Civic Center Boulevard, Philadelphia, PA 19104, United States. mcinnesa@email.chop.edu
- Resuscitation. 2012 Dec 1;83(12):1462-6.
AimPerformance of high quality CPR is associated with improved resuscitation outcomes. This study investigates code leader ability to recall CPR error during post-event interviews when CPR recording/audiovisual feedback-enabled defibrillators are deployed.Patients And MethodsPhysician code leaders were interviewed within 24h of 44 in-hospital pediatric cardiac arrests to assess their ability to recall if CPR error occurred during the event. Actual CPR quality was assessed using quantitative recording/feedback-enabled defibrillators. CPR error was defined as an overall average event chest compression (CC) rate <95/min, depth < 38 mm, ventilation rate >10/min, or any interruptions in CPR >10s. We hypothesized that code leaders would recall error when it actually occurred ≥ 75% of the time when assisted by audiovisual alerts from a CPR recording feedback-enabled defibrillators (analysis by χ(2)).Results810 min from 44 cardiac arrest events yielded 40 complete data sets (actual and interview); ventilation data was available in 24. Actual CPR error was present in 3/40 events for rate, 4/40 for depth, 32/40 for interruptions >10s, and 17/24 for ventilation frequency. In post-event interviews, code leaders recalled these errors in 0/3 (0%) for rate, 0/4 (0%) for depth, and 19/32 (59%) for interruptions >10s. Code leaders recalled these CPR quality errors less than 75% of the time for rate (p=0.06), for depth (p<0.01), and for CPR interruption (p=0.04). Quantification of errors not recalled: missed rate error median=94 CC/min (IQR 93-95), missed depth error median=36 mm (IQR 35.5-36.5), missed CPR interruption >10s median=18s (IQR 14.4-28.9). Code leaders did recall the presence of excessive ventilation in 16/17 (94%) of events (p=0.07).ConclusionDespite assistance by CPR recording/feedback-enabled defibrillators, pediatric code leaders fail to recall important CPR quality errors for CC rate, depth, and interruptions during post-cardiac arrest interviews.Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:

- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.