    Ability of code leaders to recall CPR quality errors during the resuscitation of older children and adolescents.

    • Andrew D McInnes, Robert M Sutton, Akira Nishisaki, Dana Niles, Jessica Leffelman, Lori Boyle, Matthew R Maltese, Robert A Berg, and Vinay M Nadkarni.
    • The Children's Hospital of Philadelphia, Department of Anesthesia and Critical Care Medicine, 34th Street and Civic Center Boulevard, Philadelphia, PA 19104, United States. mcinnesa@email.chop.edu
    • Resuscitation. 2012 Dec 1;83(12):1462-6.

    AimPerformance of high quality CPR is associated with improved resuscitation outcomes. This study investigates code leader ability to recall CPR error during post-event interviews when CPR recording/audiovisual feedback-enabled defibrillators are deployed.Patients And MethodsPhysician code leaders were interviewed within 24h of 44 in-hospital pediatric cardiac arrests to assess their ability to recall if CPR error occurred during the event. Actual CPR quality was assessed using quantitative recording/feedback-enabled defibrillators. CPR error was defined as an overall average event chest compression (CC) rate <95/min, depth < 38 mm, ventilation rate >10/min, or any interruptions in CPR >10s. We hypothesized that code leaders would recall error when it actually occurred ≥ 75% of the time when assisted by audiovisual alerts from a CPR recording feedback-enabled defibrillators (analysis by χ(2)).Results810 min from 44 cardiac arrest events yielded 40 complete data sets (actual and interview); ventilation data was available in 24. Actual CPR error was present in 3/40 events for rate, 4/40 for depth, 32/40 for interruptions >10s, and 17/24 for ventilation frequency. In post-event interviews, code leaders recalled these errors in 0/3 (0%) for rate, 0/4 (0%) for depth, and 19/32 (59%) for interruptions >10s. Code leaders recalled these CPR quality errors less than 75% of the time for rate (p=0.06), for depth (p<0.01), and for CPR interruption (p=0.04). Quantification of errors not recalled: missed rate error median=94 CC/min (IQR 93-95), missed depth error median=36 mm (IQR 35.5-36.5), missed CPR interruption >10s median=18s (IQR 14.4-28.9). Code leaders did recall the presence of excessive ventilation in 16/17 (94%) of events (p=0.07).ConclusionDespite assistance by CPR recording/feedback-enabled defibrillators, pediatric code leaders fail to recall important CPR quality errors for CC rate, depth, and interruptions during post-cardiac arrest interviews.Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,704,841 articles already indexed!

We guarantee your privacy. Your email address will not be shared.