• Spine · Dec 2015

    Comparative Study

    BIOMECHANICAL COMPARISON OF SACRAL FIXATION CHARACTERISTICS OF STANDARD S1-PEDICLE SCREW FIXATION VS A NOVEL CONSTRAINED S1-DUAL-SCREW ANCHORAGE IN THE S1-PEDICLE AND S1-ALAR BONE.

    • Michael Mayer, Daniel Stephan, Herbert Resch, Peter Augat, Alexander Auffarth, Martina Blocher, Lukas Ernstbrunner, Wolfgang Hitzl, Henri Defossez, Renaud Rouge, and Heiko Koller.
    • *German Scoliosis Center, Werner-Wicker-Klinik Bad Wildungen, Im Kreuzfeld 4, 34537 Bad Wildungen, Germany†Biomechanical Laboratory, Trauma Center Murnau, Prof.-Küntscher-Str. 8, 82418 Murnau, Germany‡Department for Traumatology and Sports Injuries, Paracelsus Medical University Salzburg, Muellner Hauptstrasse 48, 5020 Salzburg, Austria§Research Office and Biostatistics, Paracelsus Medical University Salzburg, Strubergasse 21, 5020 Salzburg, Austria||DePuySynthesSpineJohnson & Johnson, Chemin Blanc 36, LeLocle 2400, Switzerland.
    • Spine. 2015 Dec 1; 40 (24): 1890-7.

    Study DesignBiomechanical Laboratory Study.ObjectiveAnalysis of the biomechanical characteristics of a novel sacral constrained dual-screw fixation device (S1-PALA), combining a S1-pedicle screw and a S1-ala screw, compared to a standard bicortical S1-pedicle screw (S1-PS) fixation.Summary Of Background DataInstrumented fusions to the sacrum are biomechanically challenging and plagued by a high risk of nonunion when S1-PS is used as the sole means of fixation. Thus, lumbopelvic fixation is increasingly selected instead, although associated with a reasonable number of instrumentation-related complications.MethodsAround 30 fresh-frozen human sacral bones were harvested and embedded after CT scans. Instrumentation was conducted in alternating order with bicortical 7.0 mm S1-PS and with the S1-PALA including a S1-PS screw and a S1-ala screw, of 7.0 and 6.0 mm diameter, respectively. Specimens were subjected to cyclic loading with increasing loads (25-250 N) until a maximum of 2000 cycles or displacement >2 mm occurred. All implant sacral units (ISUs) were subject to coaxial pullout tests. Failure load, number of ISUs surpassing 2000 cycles, number of cycles, and loads at failure were recorded and compared.ResultsDonors' age averaged 77 ± 14.2 years, and BMD was 115 ± 64.8 mgCA-HA/ml. Total working length of screws implanted was 90 ± 8.6 mm in the S1-PALA group and 46 ± 5 mm in the S1-PS group (P = 0.0002). In the S1-PALA group, displacement >2 mm occurred after 845 ± 325 cycles at 149 ± 41 N compared to 512 ± 281 cycles at 106 ± 36 N in the S1-PS group (P = 0.004; P = 0.002). In coaxial pull-out testing, failure load was 2118.1 ± 1166 N at a displacement of 2.5 ± 1 mm in the S1-PALA group compared to 1375.6 ± 750.1 N at a displacement of 1.6 ± 0.5 mm in the S1-PS group (P = 0.0007; P = 0.0003).ConclusionThe novel sacral constrained dual-screw anchorage (S1-PALA) significantly improved holding strength after cyclic loading compared to S1-PS. The S1-PALA demonstrated mechanical potential as a useful adjunct in the armamentarium of lumbosacral fixations indicated in cases that need advanced construct stability, but where instrumentation to the ilium or distal dissection to S2 should be avoided.Level Of EvidenceN/A.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…