• Shock · Jan 2013

    Functional fibrinogen assay indicates that fibrinogen is critical in correcting abnormal clot strength following trauma.

    • Jeffrey N Harr, Ernest E Moore, Arsen Ghasabyan, Theresa L Chin, Angela Sauaia, Anirban Banerjee, and Christopher C Silliman.
    • Department of Surgery, University of Colorado Denver, Aurora, CO, USA.
    • Shock. 2013 Jan 1; 39 (1): 45-9.

    AbstractThromboelastography (TEG) is emerging as the standard in the management of acute coagulopathies in injured patients. Although TEG is sensitive in detecting abnormalities in clot strength, one shortcoming is differentiating between fibrinogen and platelet contributions to clot integrity. Current American algorithms suggest platelet transfusion, whereas European guidelines suggest fibrinogen concentrates for correcting low clot strength. Therefore, we hypothesized that a TEG-based functional fibrinogen (FF) assay would assess the contribution of fibrinogen and platelets to clot strength and provide insight to transfusion priorities. Blood samples were obtained from trauma patients on arrival to the emergency department or who were admitted to the surgical intensive care unit (n = 68). Citrated kaolin TEG, FF, and von Clauss fibrinogen levels (plasma-based clinical standard) were measured. Correlations were assessed using linear regression models. In vitro studies were also performed with adding fibrinogen concentrates to blood collected from healthy volunteers (n = 10). Functional fibrinogen and citrated kaolin TEG parameters were measured. Functional fibrinogen strongly correlated with von Clauss fibrinogen levels (R = 0.87) and clot strength (R = 0.80). The mean fibrinogen contribution to clot strength was 30%; however, there was a direct linear relationship with fibrinogen level and percent fibrinogen contribution to clot strength (R = 0.83). Traditional TEG parameters associated with fibrinogen activity (α angle and kinetic time) had significantly lower correlations with FF (R = 0.70 and 0.35). Furthermore, platelet count had only a moderate correlation to clot strength (R = 0.51). The addition of fibrinogen concentrate in in vitro studies increased clot strength (MA) (60.44 ± 1.48 to 68.12 ± 1.39) and percent fibrinogen contribution to clot strength (23.8% ± 1.8% to 37.7% ± 2.5%). Functional fibrinogen can be performed rapidly with TEG and correlates well with the standard von Clauss fibrinogen assay. Both fibrinogen and platelet contribution of clot strength can be derived from FF. Moreover, FF had a stronger correlation to clot strength, and increased levels were directly associated with increased percent contribution to clot strength. In vitro studies also demonstrated an increase in FF, clot strength, and percent fibrinogen contribution to clot strength with the addition of fibrinogen concentrate. These data suggest that fibrinogen should be addressed early in trauma patients manifesting acute coagulopathy of trauma.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…