Intensive care medicine · Oct 2010
Speech effects of a speaking valve versus external PEEP in tracheostomized ventilator-dependent neuromuscular patients.
- Hélène Prigent, Marine Garguilo, Sophie Pascal, Samuel Pouplin, Justine Bouteille, Michèle Lejaille, David Orlikowski, and Frédéric Lofaso.
- Services de Physiologie, Explorations Fonctionnelles, Réanimation Médicale, Rééducation Fonctionnelle, et Centre d'Investigation Clinique et d'Innovation Technologique (Inserm Unit 805), Hôpital Raymond Poincaré, AP-HP, 92380, Garches, France. helene.prigent@rpc.ap-hop-paris.fr.
- Intensive Care Med. 2010 Oct 1; 36 (10): 1681-1687.
PurposeMany patients with respiratory failure related to neuromuscular disease receive chronic invasive ventilation through a tracheostomy. Improving quality of life, of which speech is an important component, is a major goal in these patients. We compared the effects on breathing and speech of low-level positive end-expiratory pressure (PEEP, 5 cmH(2)O) and of a Passy-Muir speaking valve (PMV) during assist-control ventilation.MethodsWe studied ten patients with neuromuscular disorders, between December 2008 and April 2009. Flow was measured using a pneumotachograph. Microphone speech recordings were subjected to both quantitative measurements and qualitative assessments; the latter consisted of both an intelligibility score (using a French adaptation of the Frenchay Dysarthria Assessment) and a perceptual score determined by two speech therapists.ResultsText reading time, perceptive score, intelligibility score, speech comfort, and respiratory comfort were similar with PEEP and PMV. During speech with 5 cmH(2)O PEEP, six of the ten patients had no return of expiratory gas to the expiratory line and, therefore, had the entire insufflated volume available for speech, a condition met during PMV use in all patients. During speech, the respiratory rate increased by at least 3 cycles/min above the backup rate in seven patients with PEEP and in none of the patients with PMV.ConclusionsLow-level PEEP is as effective as PMV in ensuring good speech quality, which might be explained by sealed expiratory line with low-level PEEP and/or respiratory rate increase during speech with PEEP observed in most of the patients.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.