Comparative Study Controlled Clinical TrialInvestigation into the effect of closed-system suctioning on the frequency of pediatric ventilator-associated pneumonia in a developing country.
- Brenda M Morrow, Rukaiya Mowzer, Richard Pitcher, and Andrew C Argent.
- Division of Paediatric Critical Care and Children's Heart Disease, School of Child and Adolescent Health, University of Cape Town, Cape Town, South Africa. brenda.morrow@uct.ac.za
- Pediatr Crit Care Me. 2012 Jan 1;13(1):e25-32.
ObjectiveTo investigate the effect of closed-system vs. open endotracheal suctioning on the frequency of ventilator-associated pneumonia and outcome in a pediatric intensive care unit in a developing country.DesignProspective observational and nonrandomized controlled clinical study.SettingA 20-bed pediatric intensive care unit in a tertiary pediatric hospital.PatientsInfants and children mechanically ventilated for >24 hrs.Intervention: Pediatric intensive care unit suctioning systems were alternated monthly. An 8-month interim analysis was planned with a priori efficacy and futility study termination boundaries set at p < .006 and p > .52, respectively.Measurements And Main ResultsDemographic, clinical, and laboratory data were prospectively recorded. Ventilator-associated pneumonia was diagnosed using the Clinical Pulmonary Infection Score, and the results were confirmed retrospectively using Centers for Disease Control criteria. A total of 250 patients (median [interquartile range] age of 3.8 [1.2-15.0] months) in 263 pediatric intensive care unit admissions were included. Fifty-nine admissions developed ventilator-associated pneumonia, with a calculated rate of 45.1 infections per 1000 ventilated days. There was no difference in characteristics or outcome between patients on closed-system suctioning (n = 83) and those on open endotracheal suctioning (n = 180). The frequencies of ventilator-associated pneumonia for patients on closed-system suctioning and open endotracheal suctioning were 20.5% and 23.3%, respectively (p = .6), reaching the a priori set limit of futility. Patients who developed ventilator-associated pneumonia spent a median (interquartile range) of 22 (13-37) and 11 (8-16) days in the hospital and pediatric intensive care unit, respectively, compared to 14.5 (10-24) and 6 (4-8) days for those without ventilator-associated pneumonia (p < .001). A 22% proportion of patients who developed ventilator-associated pneumonia died compared to 11.3% of those without ventilator-associated pneumonia (p = .03). Risk factors for ventilator-associated pneumonia identified on multiple logistic regression were duration of mechanical ventilation, transport out of the pediatric intensive care unit, and blood transfusion.ConclusionClosed-system suctioning did not affect the frequency of ventilator-associated pneumonia or patient outcome in this setting.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.