-
Pediatr Crit Care Me · Jan 2012
Comparative StudyCentral venous catheter sampling of low molecular heparin levels: an approach to increasing result reliability.
- M E Bauman, Mark Belletrutti, M L Bauman, and M P Massicotte.
- Stollery Children's Hospital, University of Alberta, Edmonton, Alberta, Canada.
- Pediatr Crit Care Me. 2012 Jan 1;13(1):1-5.
BackgroundThe low molecular weight heparin effect in children is monitored using the anti-factor Xa level. Venipuncture is recommended; however, central venous catheter blood sampling is often necessary. Heparin infused through central venous catheters may contaminate central venous catheter blood samples, preventing reliable anti-factor Xa level measurement. Simultaneous anti-factor Xa/partial thromboplastin time measurement with central venous catheter blood sampling may predict anti-factor Xa reliability.ObjectivesTo determine the prevalence of heparin contamination as measured by the partial thromboplastin time/anti-factor Xa in central venous catheter blood samples and whether careful sampling could minimize heparin contamination of anti-factor Xa levels from central venous catheter blood sampling.MethodsSimultaneous partial thromboplastin time/anti-factor Xa measurements from central venous catheter blood sampling determined the prevalence of heparin contamination of central venous catheter blood samples. In phase II, children receiving low molecular weight heparin had routine central venous catheter blood sampling to measure the peak anti-factor Xa and the simultaneous partial thromboplastin time. Anti-factor Xa levels with a partial thromboplastin time of >40 secs (pair 1) were identified; there was no low molecular weight heparin dose change, and the paired sample was repeated using a careful sampling technique (pair 2). Pairs 1 and 2 were compared to determine the efficiency of the sampling technique in removing heparin from the central venous catheter blood samples.ResultsIn phase I, 100 children had 485 paired anti-factor Xa/partial thromboplastin time central venous catheter blood samples with 29% ± 4.1% (95% confidence interval 25% to 33%) anti-factor Xa with partial thromboplastin times of >40 secs. In phase II, 43 children had 129 paired anti-factor Xa/partial thromboplastin time samples with partial thromboplastin times of >40 secs. The pair 1 mean partial thromboplastin times/anti-factor Xa levels were 109.8 secs (SD 53.1, range 34.0 to >200 secs) and 1.03 units/mL (SD 0.56, range 0.26-4.2 units/mL). Repeated partial thromboplastin times/anti-factor Xa levels (pair 2) were significantly decreased from those of pair 1 (p < .001) with means of 58.5 secs (SD 21.2, range 22-152 secs) vs. 109.8 secs (SD 53.1, range 34.0 to > 200 secs, p < .001) and 0.63 unit/mL (SD 0.30, range 0.02-1.77 units/mL) vs. 1.03 units/mL (SD 0.56, range 0.26-4.2 units/mL), respectively.ConclusionsMeasurement of the partial thromboplastin time performed in combination with that of the anti-factor Xa level can be used to assist health practitioners to identify unfractionated heparin contamination of anti-factor Xa levels drawn from central venous catheters. A careful sampling technique may minimize heparin contamination in central venous catheter blood samples.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.