Anesthesia and analgesia · Dec 2015
Occupational Chronic Sevoflurane Exposure in the Everyday Reality of the Anesthesia Workplace.
- Jennifer Herzog-Niescery, Nikolaj Matthias Botteck, Heike Vogelsang, Philipp Gude, Horst Bartz, Thomas Peter Weber, and Hans-Martin Seipp.
- From the *Department of Anesthesiology, Katholisches Klinikum Bochum, St. Josef- and St. Elisabeth Hospital, Ruhr-University of Bochum, Bochum, Germany; and †Department of Hygiene, Environmental Engineering and Biotechnology, University of Applied Sciences, Giessen, Germany.
- Anesth. Analg. 2015 Dec 1;121(6):1519-28.
BackgroundAlthough sevoflurane is one of the most commonly used volatile anesthetics in clinical practice, anesthesiologists are hardly aware of their individual occupational chronic sevoflurane exposure. Therefore, we studied sevoflurane concentrations in the anesthesiologists' breathing zones, depending on the kind of induction for general anesthesia, the used airway device, and the type of airflow system in the operating room. Furthermore, sevoflurane baselines and typical peaks during general anesthesia were determined.MethodsMeasurements were performed with the LumaSense Photoacoustic Gas Monitor. As we detected the gas monitor's cross-sensitivity reactions between sevoflurane and disinfectants, regression lines for customarily used disinfectants during surgery (Cutasept®, Octeniderm®) and their alcoholic components were initially analyzed. Hospital sevoflurane concentrations were thereafter measured during elective surgery in 119 patients. The amount of inhaled sevoflurane by anesthesiologists was estimated according to mVA = cVA × V × t × ρVA aer.ResultsInduction of general anesthesia stopped after tracheal intubation with the patient's expiratory sevoflurane concentration of 1.5%. Thereby, inhalational inductions (INH) caused higher sevoflurane concentrations than IV inductions (mean [SD]: (Equation is included in full-text article.)[ppm] INH 2.43 ± 1.91 versus IV 0.62 ± 0.33, P < 0.001; mVA [mg] INH 1.95 ± 1.54 versus IV 0.30 ± 0.22, P < 0.001). The use of laryngeal mask airway (LMA™) led to generally higher sevoflurane concentrations in the anesthesiologists' breathing zones than tracheal tubes ((Equation is included in full-text article.)[ppm] tube 0.37 ± 0.16 versus LMA™ 0.79 ± 0.53, P = 0.009; (Equation is included in full-text article.)[ppm] tube 1.91 ± 0.91 versus LMA™ 2.91 ± 1.81, P = 0.057; mVA [mg] tube 1.47 ± 0.64 versus LMA™ 2.73 ± 1.81, P = 0.019). Sevoflurane concentrations were trended higher during surgery in operating rooms with turbulent flow (TF) air-conditioning systems compared with laminar flow (LF) air-conditioning systems ((Equation is included in full-text article.)[ppm] TF 0.29 ± 0.12 versus LF 0.13 ± 0.06, P = 0.012; mVA [mg/h] TF 1.16 ± 0.50 versus LF 0.51 ± 0.25, P = 0.007).ConclusionsAnesthesiologists are chronically exposed to trace concentrations of sevoflurane during work. Inhalational inductions, LMA™, and TF air-conditioning systems in particular are associated with higher sevoflurane exposure. However, the amount of inhaled sevoflurane per day was lower than expected, perhaps because concentrations in previous measurements could be overestimated (10%-15%) because of the cross-sensitivity reaction.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.