• Anesthesia and analgesia · Mar 2016

    Observational Study

    Blood Bupivacaine Concentrations After Transversus Abdominis Plane Block in Neonates: A Prospective Observational Study.

    • Santhanam Suresh and Gildasio S De Oliveira.
    • From the Department of Pediatric Anesthesia, Ann & Robert H. Lurie Children's Hospital of Chicago, Northwestern University, Chicago, Illinois; and Department of Anesthesiology, Feinberg School of Medicine, Northwestern University, Chicago, Illinois.
    • Anesth. Analg. 2016 Mar 1; 122 (3): 814-817.

    BackgroundUntreated pain can have instant and prolonged consequences to behavioral and neurologic outcomes in neonates. Although the use of transversus abdominis plane (TAP) block to minimize postsurgical pain has been demonstrated in neonates, no data regarding the safety of this procedure are available for this patient population. For instance, it is unknown whether plasma levels of local anesthetics are safe in neonates after TAP blocks. The main objective of the current investigation was to evaluate plasma bupivacaine concentrations in neonates having an ultrasound-guided TAP block.MethodsThe study was a prospective, observational study. After general anesthesia was induced, neonates received an ultrasound-guided TAP block with 0.125% bupivacaine and a total volume of 1 mL/kg. Dried blood spot samples were obtained and analyzed for bupivacaine levels at 0, 5, 15, 30, 60, 120 minutes, 4, and 24 hours after the TAP block.ResultsTen neonates were included in the study. The highest 99% upper prediction limit for blood concentration, 0.38 µg/mL, occurred at the 30-minute interval, but it was significantly lower than potentially toxic plasma levels (1.5-2.0 µg/mL). The highest individual concentration was 0.26 µg/mL and occurred at the 30-minute interval. None of the patients demonstrated any potential signs of local anesthetic toxicity.ConclusionsOur results suggest a low risk of local anesthetic toxicity in neonates after a TAP block. Future studies to determine the efficacy of the TAP block to minimize postsurgical pain in this patient population are warranted.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,694,794 articles already indexed!

We guarantee your privacy. Your email address will not be shared.