• Pediatr Crit Care Me · Mar 2012

    Lamellar body count and stable microbubble test on tracheal aspirates from infants for the diagnosis of respiratory distress syndrome.

    • Jefferson P Piva, Ana Cláudia C G Vieira, and Terezinha P Munhoz.
    • Faculty of Nursing, Universidade Federal de Pelotas, Pelotas, Brazil.
    • Pediatr Crit Care Me. 2012 Mar 1;13(2):178-82.

    ObjectivesTo evaluate the performance of lamellar body count in tracheal aspirates from intubated preterm babies to predict respiratory distress syndrome.DesignCase-control study.SettingThree neonatal intensive care units.PatientsSeventy-two patients not older than 3 days were included in the study, 38 preterm infants with respiratory distress syndrome, 16 preterms without respiratory distress syndrome, and 18 term infants. All required mechanical ventilation.InterventionsLamellar body count was performed in an automated cell counter. Tracheal samples were diluted in dithiothreitol without centrifugation and kept frozen at -20°C until use. Samples were placed in a dithiothreitol-containing test tube at a ratio of one part tracheal aspirate to six parts dithiothreitol solution, vortexed for 10 secs, and aspirated by the cell counter. Lamellar body count was performed using the platelet channel. All results were multiplied by seven. The stable microbubble test was done for comparison.MeasurementsLamellar body count and stable microbubble test.Main ResultsLamellar body count was significantly lower in the respiratory distress syndrome group compared with the non respiratory distress syndrome preterm group and also with the term group. The median and interquartile range obtained for lamellar body count were 38,500/μL (14,000-112,000) for the respiratory distress syndrome group, 822,500/μL (442,000-962,500) for the non respiratory distress syndrome preterm group, and 633,000/μL (322,000-1,608,000) for the term group (p < .001). The sensitivity and specificity of lamellar body count and stable microbubble test for the diagnosis of respiratory distress syndrome were calculated, taking into consideration the respiratory distress syndrome and the non respiratory distress syndrome preterm groups. Considering a cutoff point of 200,000 lamellar bodies/μL, lamellar body count sensitivity was 92.1% (95% confidence interval 78.6-98.3) and lamellar body count specificity was 93.8% (95% confidence interval 69.8-99.8). The area under the curve was 0.94 (95% confidence interval 0.84-1.00).ConclusionsLamellar body count and stable microbubble test can be rapidly and easily performed on tracheal aspirates and they seem to have very good performance for diagnosing respiratory distress syndrome in intubated patients.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.