• Pediatr Crit Care Me · Nov 2011

    Randomized Controlled Trial

    Value of continuous glucose monitoring for minimizing severe hypoglycemia during tight glycemic control.

    • Garry M Steil, Monica Langer, Karen Jaeger, Jamin Alexander, Michael Gaies, and Michael S D Agus.
    • Department of Surgery and Medicine, Children's Hospital, Boston, MA, USA.
    • Pediatr Crit Care Me. 2011 Nov 1;12(6):643-8.

    ObjectiveTight glycemic control can potentially reduce morbidity and mortality in the intensive care unit but increases the risk of hypoglycemia. The most effective means to avoid hypoglycemia is to obtain frequent blood glucose samples, but this increases the burden to nursing staff. The objective of this study was to assess the ability of a real-time continuous glucose monitor to reduce hypoglycemia (blood glucose <60 mg/dL [3.3 mmol/L]) during standard care or tight glycemic control effected with a proportional integral derivative insulin titration algorithm.DesignReal-time continuous glucose monitor profiles obtained from an ongoing prospective randomized trial of tight glycemic control were retrospectively analyzed to determine whether the continuous glucose measure had prevented instances of hypoglycemia.SettingCardiac intensive care unit.PatientsChildren 3 yrs of age or younger undergoing cardiac surgery were studied.InterventionsIntravenous insulin infusion and rescue glucose guided by the real-time continuous glucose monitor and the proportional integral derivative algorithm in the tight glycemic control arm (n = 155; target glucose 80-110 mg/dL [4.4-6.1 mmol/L]) and the real-time continuous glucose monitor in the standard care arm (n = 156).Measurements And Main ResultsNo reduction in hypoglycemia was observed with real-time continuous glucose monitor alarms set at 60 mg/dL (3.3 mmol/L) (zero of 19 occurrences of blood glucose <60 mg/dL [3.3 mmol/L] detected); 18 of 40 subsequent incidences of hypoglycemia were detected after the alarm threshold was increased to 70 mg/dL (3.9 mmol/L). In the tight glycemic control arm, eight incidences were reduced in duration and an additional eight events were prevented with intravenous glucose. In the standard care arm, three of nine occurrences of hypoglycemia were detected with the duration reduced in all cases. On average, one to two false hypoglycemia alarms were observed in each patient.ConclusionsThe real-time continuous glucose monitor in combination with proportional integral derivative control can reduce hypoglycemia during tight glycemic control. The real-time continuous glucose monitor can also reduce hypoglycemia during standard care. However, false alarms increase the overall nursing workload.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.