• Pediatr Crit Care Me · Mar 2012

    Capillary refill time and cardiac output in children undergoing cardiac catheterization.

    • Anna-Theresa Lobos, Suzie Lee, and Kusum Menon.
    • Division of Critical Care, University of Ottawa, Children's Hospital of Eastern Ontario, Ottawa, Ontario, Canada. alobos@cheo.on.ca
    • Pediatr Crit Care Me. 2012 Mar 1;13(2):136-40.

    ObjectiveMany pediatric healthcare providers believe that capillary refill time is a measure of perfusion and cardiac output in children. Despite its widespread use, there are no studies examining the relationship of capillary refill time to cardiac output in noncritically ill children. This study examined the inter-rater reliability of capillary refill time and its relationship to hemoglobin and with cardiac output in pediatric patients undergoing cardiac catheterization.DesignProspective observational study.SettingTertiary care pediatric hospital.PatientsA total of 58 children, ages 0.3-17 yrs, with congenital heart disease undergoing cardiac catheterization.InterventionsTwo clinicians performed two measurements of capillary refill time in a standardized fashion on 58 children undergoing cardiac catheterization. Cardiac output was determined by the Fick method within 15 mins of the first assessment of capillary refill time (time 1).Measurements And Main ResultsCapillary refill time and cardiac output measurements were obtained in 44 children, and 108 paired measurements of capillary refill time were obtained to assess inter-rater reliability. The mean capillary refill time was 1.2 secs (±0.5 secs), and the mean cardiac output was 3.6 L/min/m (2.2-5.7 L/min/m). The inter-rater intraclass correlation coefficient was 0.12 (time 1) (95% confidence interval -0.15 to +0.37) and was 0.32 (95% confidence interval 0.058-0.54) at the end of the catheterization (time 2). A significant association was noted between average capillary refill time at time 1 and hemoglobin, with higher hemoglobin correlating with longer capillary refill time (p = .015). There was no significant correlation between the average capillary refill time taken at the time of cardiac output measurement (time 1) and measured cardiac output (r = .331, 95% confidence interval for r, .066-.552).ConclusionsWe found that the inter-rater reliability of capillary refill time was poor and variable under controlled conditions and capillary refill time was not correlated with cardiac output in anesthetized nonacutely ill pediatric patients undergoing cardiac catheterization. Caution should be used in inferring cardiac output from capillary refill time measurements alone.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.