-
- Ertunc Altiok, Michael Becker, Sandra Hamada, Sebastian Reith, Nikolaus Marx, and Rainer Hoffmann.
- Medical Clinic I, University RWTH Aachen, Pauwelsstraße 30, 52057, Aachen, Germany.
- Clin Res Cardiol. 2011 Aug 1;100(8):675-81.
BackgroundPercutaneous edge-to-edge repair with the MitraClip device has been shown to allow effective treatment of mitral regurgitation. It is mainly guided by transesophageal echocardiography while fluoroscopic guidance is of less importance. The impact of real-time three-dimensional transesophageal echocardiography (RT 3-D TEE) for guidance of this complex interventional procedure has not been evaluated.MethodsIn 28 high-surgical risk patients with moderate or severe mitral regurgitation (mean age 67 ± 10 years; 15 male), 2-D and RT 3-D TEE were used for the guidance of percutaneous edge-to-edge mitral valve repair using the MitraClip device. We performed a structured analysis to compare information and guidance capacity provided by RT 3-D TEE compared to 2-D TEE.ResultsRT 3-D TEE was found to provide advantages in 9 of 11 steps of the percutaneous mitral repair procedure. The advantages related to optimized definition of the transseptal puncture site, improved guidance of the clip delivery system towards the mitral valve, precise positioning of the clip delivery system simultaneously in anterior-posterior and lateral-medial direction above the mitral valve considering mitral valve scallops A2 and P2 and valvular regurgitation jet position, adjustment of the opened clip-arms perpendicular to the commissural line, visualization of the clip position relative to the valvular orifice and of the remaining regurgitant jet after clip closure from atrial as well as ventricular views providing double orifice images and thereby allowing confirmation or rejection of clip position in medial-lateral direction. RT 3-D TEE was inferior to 2-D TEE for leaflet grasping and analysis of leaflet insertion.ConclusionIn complex interventional edge-to-edge repair with the MitraClip device requiring optimal spatial information RT 3-D TEE allows improved guidance of the procedure. RT 3-D TEE guidance compared with 2-D TEE guidance alone resulted in greater operator confidence to adequately perform the procedure.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.