-
Pacing Clin Electrophysiol · May 2000
Age dependency of sensing performance and AV synchrony in single lead VDD pacing.
- U K Wiegand, J Potratz, F Bode, R Schneider, W Peters, H Bonnemeier, and H A Katus.
- Medical University of Luebeck, Department of Internal Medicine II, Germany.
- Pacing Clin Electrophysiol. 2000 May 1;23(5):863-9.
AbstractImplantation of single lead VDD pacemakers is an established therapeutic option in patients with AV block and normal sinus node function. However, related to occurrence of sinus node disease and atrial undersensing, there is concern whether VDD devices are appropriate in physically active young patients. Two hundred thirty-two consecutive patients with isolated AV block and VDD pacemakers were investigated. This population was subdivided into quartiles of 58 patients according to age at time of inclusion: 26.2-59.4 years (group A), 59.5-70.1 years (group B), 70.2-81.0 years (group C), and 81.1-92.5 years (group D). Follow-up visits included pacemaker telemetry, Holter monitoring, and exercise testing. Patients were visited at 2 and 12 weeks after implantation thereafter followed by 6-month intervals. Mean follow-up period was 35 +/- 14 months. Three months after implantation, atrial sensing threshold was significantly higher in young patients: 1.18 +/- 0.58 mV (group A) versus 0.79 +/- 0.35 mV (group B), 0.68 +/- 0.33 mV (group C), and 0.60 +/- 0.25 mV (group D), P < 0.001 for comparison of group A to all other groups. Atrial undersensing was observed less frequently in young patients: 6.9% (group A) versus 17.2% (group B), 24.1% (group C), and 27.6% (group D), P = 0.025 for intergroup comparisons. Sinus node dysfunction did not occur in group A. Atrial arrhythmias and loss of AV synchronized pacing mode occurred rarely in young patients: 0.6% (0.4%) per year in group A versus 1.3% (1.3%) in group B, 3.9% (3.4%) in group C, and 5.7% (7.4%) per year in group D, P < 0.01 for intergroup comparisons. Our data show good atrial sensing performance, low incidence of sinus node dysfunction, and few atrial arrhythmias in young patients with VDD pacing for AV block. Thus, single lead VDD pacing can be recommended particularly for young patients with AV block.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.