• Pacing Clin Electrophysiol · Apr 1996

    VDD(R) pacing: short- and long-term stability of atrial sensing with a single lead system.

    • B Naegeli, S Osswald, M Pfisterer, and F Burkart.
    • Department of Internal Medicine, University Hospital Basel, Switzerland.
    • Pacing Clin Electrophysiol. 1996 Apr 1;19(4 Pt 1):455-64.

    BackgroundRecent studies have shown that the atrial signal can reliably be sensed for VDD(R) pacing via atrial floating electrodes incorporated in a single-pass lead. However, there remains concern about the long-term stability of atrial sensing and proper VDD function under real-life conditions. This study investigated the long-term reliability of atrial sensing and atrioventricular synchronous pacing using a new single lead VDD(R) pacing system.Methods And ResultsIn 20 consecutive patients (ages 71 +/- 14 years) with normal sinus node function and high-degree heart block, a single lead VDD(R) pacemaker (Unity, Intermedics) was implanted. Atrial sensing was studied at implantation, at discharge, and at 1, 3, 6, 12, and 18 months of follow-up. At implant, the measured P wave amplitude was 2.3 +/- 1.2 mV. By telemetry, the atrial sensing threshold was 0.79 +/- 0.41 mV at discharge, 0.75 +/- 0.43 mV at 1 month, 0.73 +/- 0.43 mV at 3 months, 0.76 +/- 0.41 mV at 6 months, 0.79 +/- 0.41 mV at 12 months, and 0.77 +/- 0.35 mV at 18 months of follow-up (P = NS). Appropriate VDD pacing was assessed by the percentage of correct atrial synchronization (PAS = atrial triggered ventricular paced complexes divided by total number of ventricular paced complexes) during repeated Holters. PAS was 99.99% +/- 0.01% at 1 month, 99.99% +/- 0.02% at 3 months, and 99.98% +/- 0.05% at 12 months of follow-up (P = NS). No atrial oversensing with inappropriate ventricular pacing was observed, neither during isometric arm exercise testing nor spontaneously during Holter monitoring.ConclusionThe long-term stability of atrial sensing with almost 100% correct atrial synchronous tracking and the lack of inappropriate pacing due to atrial oversensing make the new Unity VDD(R) system a highly reliable single lead pacing system. In view of the lower costs and the ease of single lead implantation, this system may offer an interesting alternative to DDD pacemakers in patients with normal sinus node function.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.