• Eur J Anaesthesiol · Jan 2003

    Breathing pattern and workload during automatic tube compensation, pressure support and T-piece trials in weaning patients.

    • R Kuhlen, M Max, R Dembinski, S Terbeck, E Jürgens, and R Rossaint.
    • University of Aachen Medical School, Department of Anesthesiology, Aachen, Germany. Ralf.Kuhlen@post.rwth-aachen.de
    • Eur J Anaesthesiol. 2003 Jan 1;20(1):10-6.

    Background And ObjectiveAutomatic tube compensation has been designed as a new ventilatory mode to compensate for the non-linear resistance of the endotracheal tube. The study investigated the effects of automatic tube compensation compared with breathing through a T-piece or pressure support during a trial of spontaneous breathing used for weaning patients from mechanical ventilation of the lungs.MethodsTwelve patients were studied who were ready for weaning after prolonged mechanical ventilation (10.2 +/- 8.4 days) due to acute respiratory failure. Patients with chronic obstructive pulmonary disease were excluded. Thirty minutes of automatic tube compensation were compared with 30 min periods of 7 cmH2O pressure support and T-piece breathing. Breathing patterns and workload indices were measured at the end of each study period.ResultsDuring T-piece breathing, the peak inspiratory flow rate (0.65 +/- 0.20 L s(-1)) and minute ventilation (8.9 +/- 2.7L min(-1)) were lower than during either pressure support (peak inspiratory flow rate 0.81 +/- 0.25 L s(-1) minute ventilation 10.2 +/- 2.3 L min(-1), respectively) or automatic tube compensation (peak inspiratory flow rate 0.75 +/- 0.26L s(-1); minute ventilation 10.8 +/- 2.7 L min(-1)). The pressure-time product as well as patients' work of breathing were comparable during automatic tube compensation (pressure-time product 214.5 +/- 104.6 cmH2O s(-1) min(-1), patient work of breathing 1.1 +/- 0.4 J L(-1)) and T-piece breathing (pressure-time product 208.3 +/- 121.6 cmH2O s(-1) min(-1), patient work of breathing 1.1 +/- 0.4 J L(-1)), whereas pressure support resulted in a significant decrease in workload indices (pressure-time product 121.2 +/- 64.1 cmH2O s(-1) min(-1), patient work of breathing 0.7 +/- 0.4 J L(-1)).ConclusionsIn weaning from mechanical lung ventilation, patients' work of breathing during spontaneous breathing trials is clearly reduced by the application of pressure support 7 cmH2O, whereas the workload during automatic tube compensation corresponded closely to the values during trials of breathing through a T-piece.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,694,794 articles already indexed!

We guarantee your privacy. Your email address will not be shared.