Obstetrics and gynecology · Oct 2012
Minimally invasive endometrial ablation device complications and use outside of the manufacturers' instructions.
- Jill Brown and Ken Blank.
- National Institute of Allergy and Infectious Diseases, Bethesda, Maryland 20892, USA. jill.brown@nih.gov
- Obstet Gynecol. 2012 Oct 1;120(4):865-70.
ObjectiveTo review the U.S. Food and Drug Administration (FDA) Manufacturer and User Facility Device Experience database for reports describing serious adverse events and adverse events reports describing use outside of the manufacturers' labeled instructions for the five FDA-approved minimally invasive endometrial ablation devices.MethodsWe queried the Manufacturer and User Facility Device Experience database for reports of device malfunction, patient injury, or death reported for each device from January 1, 2005 to December 31, 2011. We reviewed U.S. reports individually for annotations of patient injury or death and tabulated the reports by type of injury and device. We identified nine categories of serious injury (death, sepsis or bacteremia, intra-abdominal abscess, uterine rupture, thermal bowel injury, mechanical bowel injury, transmural uterine thermal injury, urologic injury, and lower genital tract or skin burns) and noted all reports citing device use outside of the manufacturers' labeled instructions. We also identified reports of hysterectomy or bowel resection attributable to an adverse event.ResultsSerious adverse events, including bowel injury (n=128), sepsis or bacteremia (n=47), intra-abdominal abscess (n=18), urologic injury (n=2), and uterine rupture (n=1) were reported. Death was also reported (n=4). Eight percent (66 of 829) of serious adverse events reports cited use outside of the manufacturers' labeled instructions, as did 7.3% (6 of 82) of reports citing need for hysterectomy and 8.7% (9 of 103) of reports of bowel resection.ConclusionThe findings from the Manufacturer and User Facility Device Experience database highlight the potential risk of serious complications related to endometrial ablation and underscore the importance of training in correct device use and familiarity with the manufacturer's labeled instructions.Level Of EvidenceIII.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.