J Minim Invasive Gynecol · Jan 2015
Hysteroscopic morcellation: review of the manufacturer and user facility device experience (MAUDE) database.
- Karina Haber, Eleanor Hawkins, Mark Levie, and Scott Chudnoff.
- Department of Obstetrics and Gynecology, Danbury Hospital, Danbury, Connecticut; Department of Minimally Invasive Gynecological Surgery, Montefiore Medical Center, Bronx, New York. Electronic address: karinahaber@gmail.com.
- J Minim Invasive Gynecol. 2015 Jan 1;22(1):110-4.
Study ObjectiveTo investigate the number and type of adverse events associated with hysteroscopic morcellation of intrauterine disease.DesignSystematic review of Manufacturer and User Device Experience (MAUDE) database from 2005 to June 2014 (Canadian Task Force classification III).Setting N/A PatientsWomen undergoing hysteroscopic surgery for removal of intrauterine polyps or myomas with use of a reciprocating morcellator.InterventionsThe MAUDE database was searched for the key words "Hysteroscope," "Hysteroscopic reciprocating morcellator," "Interlace," "MyoSure," "Smith & Nephew," and "TRUCLEAR," to identify reported incidences of device malfunction, injury, or death. A total of 119 adverse events were analyzed. Reports were reviewed individually and categorized by date of occurrence, type of morcellation device, type of complication, and a brief description. Each company was contacted to provide an estimate of the number of procedures performed or units sold to date.Measurements And Main ResultsFrom 2005 to June 2014, 119 adverse events were reported to the MAUDE database. On the basis of severity, adverse events were categorized as major or minor complications. Major events included intubation/admission to an intensive care unit (n = 14), bowel damage (n = 12), hysterectomy (n = 6), and death (n = 2). Minor events included uterine perforation requiring no other treatment (n = 29), device failure (n = 25), uncomplicated fluid overload (n = 19), postoperative bleeding controlled using noninvasive measures (n = 6), and pelvic infection (n = 4). These events were then categorized according to manufacturer. The number of adverse events reported to the MAUDE database was divided by the total units sold as a surrogate for the estimated number of procedures performed. Understanding the limitation of the numbers used as a numerator and denominator, we concluded that adverse events complicated hysteroscopic morcellation in <0.1% cases.ConclusionsThe suction-based, mechanical energy, rotating tubular cutting system was developed to overcome adverse events that occur during traditional resectoscopy. On the basis of acknowledged limited information from the MAUDE database, it seems that life-threatening complications such as fluid overload, uterine perforation, and bleeding do occur with hysteroscopic morcellation but less frequently than with traditional electrocautery.Copyright © 2015 AAGL. Published by Elsevier Inc. All rights reserved.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.