Critical care medicine · Nov 2009
Immortal time bias in critical care research: application of time-varying Cox regression for observational cohort studies.
- Ayumi K Shintani, Timothy D Girard, Svetlana K Eden, Patrick G Arbogast, Karel G M Moons, and E Wesley Ely.
- Department of Biostatistics, Division of Allergy, Pulmonary, and Critical Care Medicine, Vanderbilt University School of Medicine, Nashville, TN, USA. ayumi.shintani@vanderbilt.edu
- Crit. Care Med. 2009 Nov 1;37(11):2939-45.
ObjectivesTo examine the bias introduced by using time-fixed methodology to analyze the effects of a time-varying exposure incurred in the intensive care unit.DesignProspective cohort and Monte Carlo simulation studies.SettingMedical and coronary intensive care units in a university hospital.PatientsA total of 224 mechanically ventilated patients.MethodsPart I was a case study analyzing the association between delirium in the intensive care unit (exposure variable) and outcomes (intensive care unit length of stay and 6-mo mortality) in a prospective cohort study. Part II was a Monte Carlo simulation generating 16,000 data sets wherein the true associations between delirium and outcomes were known before analysis. In both parts, we assessed associations between delirium in the intensive care unit and outcomes (intensive care unit length of stay and mortality), using time-fixed vs. time-varying Cox regression methodology.Measurements And Main ResultsIn the case study, delirium analyzed as a time-fixed variable was associated with a delayed intensive care unit discharge (adjusted hazard ratio = 1.9, 95% confidence interval, 1.3-2.7, p < .001), but no association was noted using a time-varying method (adjusted hazard ratio = 1.1, 95% confidence interval = 0.7-1.6, p = .70). Alternatively, delirium analyzed as a time-fixed variable was not associated with 6-mo mortality (adjusted hazard ratio = 2.9, 95% confidence interval, 0.9-5.0, p = .09), whereas delirium analyzed as a time-varying variable was associated with increased mortality (adjusted hazard ratio = 3.2, 95% confidence interval, 1.4-7.7, p = .008). In the simulation study, time-fixed methods produced erroneous results in 97.1% of the data sets with no true association; time-varying methods produced erroneous results in only 3.7%. Similarly, time-fixed methods produced biased results when a true association was present, whereas time-varying methods produced accurate results.ConclusionsStudies using a time-fixed analytic approach to understand relationships between exposures and clinical outcomes can result in considerable bias when the variables overlap temporally in occurrence. Those conducting such studies, and clinicians reading them, should ensure that time-varying exposures are correctly analyzed to avoid biased conclusions.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.