-
Acta Anaesthesiol Scand · Apr 2010
Randomized Controlled TrialPredictive ability of propofol effect-site concentrations during fast and slow infusion rates.
- P O Sepúlveda, L I Cortínez, A Recart, and H R Muñoz.
- Departamento de Anestesiología, Facultad de Medicina, Clínica Alemana-Universidad del Desarrollo, Santiago, Chile.
- Acta Anaesthesiol Scand. 2010 Apr 1;54(4):447-52.
BackgroundThe performance of propofol effect-site pharmacokinetic models during target-controlled infusion (TCI) might be affected by propofol administration rate. This study compares the predictive ability of three effect-site pharmacokinetic models during fast and slow infusion rates, utilizing the cerebral state index (CSI) as a monitor of consciousness.MethodsSixteen healthy volunteers, 21-45 years of age, were randomly assigned to receive either a bolus dose of propofol 1.8 mg/kg at a rate of 1200 ml/h or an infusion of 12 mg/kg/h until 3-5 min after loss of consciousness (LOC). After spontaneous recovery of the CSI, the bolus was administered to patients who had first received the infusion and vice versa. The study was completed after spontaneous recovery of CSI following the second dose scheme. LOC was assessed and recorded when it occurred. Adequacies of model predictions during both administration schemes were assessed by comparing the effect-site concentrations estimated at the time of LOC during the bolus dose and during the infusion scheme.ResultsLOC occurred 0.97 +/- 0.29 min after the bolus dose and 6.77 +/- 3.82 min after beginning the infusion scheme (P<0.05). The Ce estimated with Schnider (ke0=0.45/min), Marsh (ke0=1.21/min) and Marsh (ke0=0.26/min) at LOC were 4.40 +/- 1.45, 3.55 +/- 0.64 and 1.28 +/- 0.44 microg/ml during the bolus dose and 2.81 +/- 0.61, 2.50 +/- 0.39 and 1.72 +/- 0.41 microg/ml, during the infusion scheme (P<0.05). The CSI values observed at LOC were 70 +/- 4 during the bolus dose and 71 +/- 2 during the infusion scheme (NS).ConclusionSpeed of infusion, within the ranges allowed by TCI pumps, significantly affects the accuracy of Ce predictions. The CSI monitor was shown to be a useful tool to predict LOC in both rapid and slow infusion schemes.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.