-
Comparative Study
Automated charting of physiological variables in anesthesia: a quantitative comparison of automated versus handwritten anesthesia records.
- J G Lerou, R Dirksen, M van Daele, G M Nijhuis, and J F Crul.
- Institute for Anesthesiology, University Hospital Nijmegen, The Netherlands.
- J Clin Monit. 1988 Jan 1;4(1):37-47.
AbstractEight physiological variables--tidal volume, breathing rate, end-tidal carbon dioxide fraction, oxygen fraction in the anesthetic circuit, oxygen saturation by pulse oximetry, systolic and diastolic blood pressure, and heart rate--recorded on-line by a commercially available automated system were compared with the same variables recorded on handwritten anesthesia records. We quantified the differences between the automated and handwritten records generated from the same 30 patients (2,412 minutes of general anesthesia for elective eye surgical procedures). Considering the design of the study, we claim that the differences between both records were caused by the incompleteness or inaccuracy of the handwritten records, except in two instances. The amounts of missing or erroneous data for these eight physiological variables were expressed as fraction ("error fractions") of the time being recorded, designated EFm and EFe, respectively. For the first five variables the EFm on the handwritten records ranged between 0.23 and 0.31, and the EFe ranged between 0.01 and 0.06. For the last three variables the EFm range was 0.08 to 0.13, and the EFe range was 0.05 to 0.11. Most of these missing or erroneous data occurred during the period of induction (first 15 minutes) and at the end of the case (last 10 minutes). The EFm and EFe during induction had increased to 0.62 and 0.26, respectively, and to 0.76 and 0.06, respectively, at the end of the case. Erroneous data were observed on the automated records for the tidal volume during induction (EFe = 0.0044) and for the oxygen fraction during maintenance (EFe = 0.0024). The effect of averaging by the recordkeeper is discussed. The results of this study indicate the clinical relevance of automated record keeping.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.