-
- Laurent Muller, Medhi Toumi, Philippe-Jean Bousquet, Béatrice Riu-Poulenc, Guillaume Louart, Damien Candela, Lana Zoric, Carey Suehs, Jean-Emmanuel de La Coussaye, Nicolas Molinari, Jean-Yves Lefrant, and AzuRéa Group.
- Division Anesthésie Réanimation Urgences Douleur, Groupe Hospitalo-Universitaire Caremeau, CHU Nîmes, Place du Professeur Robert Debré, Nîmes, France.
- Anesthesiology. 2011 Sep 1;115(3):541-7.
BackgroundPredicting fluid responsiveness remains a difficult question in hemodynamically unstable patients. The author's objective was to test whether noninvasive assessment by transthoracic echocardiography of subaortic velocity time index (VTI) variation after a low volume of fluid infusion (100 ml hydroxyethyl starch) can predict fluid responsiveness.MethodsThirty-nine critically ill ventilated and sedated patients with acute circulatory failure were prospectively studied. Subaortic VTI was measured by transthoracic echocardiography before fluid infusion (baseline), after 100 ml hydroxyethyl starch infusion over 1 min, and after an additional infusion of 400 ml hydroxyethyl starch over 14 min. The authors measured the variation of VTI after 100 ml fluid (ΔVTI 100) for each patient. Receiver operating characteristic curves were generated for (ΔVTI 100). When available, receiver operating characteristic curves also were generated for pulse pressure variation and central venous pressure.ResultsAfter 500 ml volume expansion, VTI increased ≥ 15% in 21 patients (54%) defined as responders. ΔVTI 100 ≥ 10% predicted fluid responsiveness with a sensitivity and specificity of 95% and 78%, respectively. The area under the receiver operating characteristic curves of ΔVTI 100 was 0.92 (95% CI: 0.78-0.98). In 29 patients, pulse pressure variation and central venous pressure also were available. In this subgroup of patients, the area under the receiver operating characteristic curves for ΔVTI 100, pulse pressure variation, and central venous pressure were 0.90 (95% CI: 0.74-0.98, P < 0.05), 0.55 (95% CI: 0.35-0.73, NS), and 0.61 (95% CI: 0.41-0.79, NS), respectively.ConclusionIn patients with low volume mechanical ventilation and acute circulatory failure, ΔVTI 100 accurately predicts fluid responsiveness.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.