• Br J Anaesth · Sep 2010

    Randomized Controlled Trial Comparative Study

    Arm-to-arm variation when evaluating neuromuscular block: an analysis of the precision and the bias and agreement between arms when using mechanomyography or acceleromyography.

    • C Claudius, L T Skovgaard, and J Viby-Mogensen.
    • Department of Anaesthesia 4231, Centre of Head and Orthopaedics, Copenhagen University Hospital, Blegdamsvej 9, 2100 Rigshospitalet, Denmark. casperclaudius@dadlnet.dk
    • Br J Anaesth. 2010 Sep 1;105(3):310-7.

    BackgroundStudies comparing acceleromyography and mechanomyography indicate that the two methods cannot be used interchangeably. However, it is uncertain to what extent differences in precision between the methods and the naturally occurring arm-to-arm variation have influenced the results of these studies. Accordingly, the purpose of this study was to examine the precision and the arm-to-arm variation, when the same method is used on both of the arms.MethodsIn the first part (n=20), mechanomyography was applied bilaterally and in the second part acceleromyography (n=20). Anaesthesia was induced with propofol and opioid, and neuromuscular block with rocuronium 0.6 mg kg(-1). The precision of the two methods and the bias and limits of agreement between the arms were evaluated using train-of-four (TOF) stimulation, without and with referral to the initial baseline value, that is, normalization.ResultsBoth methods were found to be precise (<5% variation) without any difference between the dominant and non-dominant arms. There were no significant biases between the arms, except for the onset time obtained with acceleromyography, which was 10% longer for the dominant arm. However, the individual differences (limits of agreement) were wide (0.20-0.25 at TOF 0.90). Normalization during recovery did not change bias or limits of agreement between the arms.ConclusionsIn the research setting, acceleromyography and mechanomyography are both precise methods without difference between the arms. Although there is no mean bias between the arms, both methods show wide individual differences (limits of agreement), which might to a large extend explain the differences often found when two different methods are compared on the contralateral arms. ClinicalTrial.gov identifier: NCT00472121; URL: http://clinicaltrials.gov/ct2/show/study/NCT00472121.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…