    Statistical analysis of blood pressure measurement errors by oscillometry during surgical operations.

    • Guocai Tao, Yan Chen, Changyun Wen, and Min Bi.
    • Department of Anesthesia, Southwest Hospital, The 3rd Military Medical University, Chongqing, China.
    • Blood Press Monit. 2011 Dec 1;16(6):285-90.

    ObjectivesAlthough a validated oscillometry sphygmomanometer satisfies the accuracy criteria of Advancement of Medical Instrumentation (AAMI), its long-term blood pressure (BP) measurement error during operations remains to be determined. We aim to (a) compare the error range throughout surgical operations with the accuracy criteria of AAMI, and (b) investigate the probabilities of occurrence of abnormal, large errors and clinically meaningful errors.MethodsBP level were measured from 270 participants using oscillometry and arterial cannulation (invasive method) in the same BP monitor throughout surgeries. Mean deviation and SD (oscillometry vs. invasive method) were calculated from 6640 sets of data and presented in the Bland-Altman Plots. Also, the average, the largest, and the smallest measurement errors (errormean, errormax, and errormin) per patient were obtained. The probability distributions of the three types of errors were shown using histograms (percentage vs. SD). In addition, the clinically meaningful large errors (≥ 10 mmHg) of the adult patients when their systolic blood pressure (SBP) values were around 90 mmHg were investigated.ResultsThe mean deviation (1.98 mmHg for SBP and 4.31 mmHg for diastolic blood pressure (DBP) satisfies the AAMI criterion (≤ 5 mmHg), but the SD (14.87 mmHg for SBP and 11.21 mmHg for DBP) exceeds the AAMI criterion (≤ 8 mmHg). The probability of errormax more than 40 mmHg is 14% for SBP and 6% for DBP. The probability of errormean more than 24 mmHg (4.07% for SBP and 1.48% for DBP), and that of errormin more than 24 mmHg (0.37% for SBP and 0.37% for DBP) are all greater than the criterion of 0.26%. The clinically meaningful errors are found in 28.78% of the adult patients.ConclusionThe SD of long-term BP measurement by our oscillometric method during operations exceeds AAMI accuracy criteria. And it is important to be aware of the abnormal large errors and clinically meaningful errors as their probabilities are rather significant. We analyze the possible cause of the major errors and deduce that similar errors may also happen with other oscillometric devices.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…