• J. Vasc. Surg. · Sep 2008

    Comparative Study

    Cerebral oximetry does not correlate with electroencephalography and somatosensory evoked potentials in determining the need for shunting during carotid endarterectomy.

    • Mark L Friedell, Jason M Clark, David A Graham, Michael R Isley, and Xiao-Feng Zhang.
    • Department of Surgical Education, Orlando Regional Healthcare, Orlando, Florida, USA. mark.friedell@orhs.org
    • J. Vasc. Surg. 2008 Sep 1;48(3):601-6.

    ObjectiveSeveral reports in the literature have described the value of regional cerebral oximetry (rSO(2)) as a neuromonitoring device during carotid endarterectomy (CEA). The use of rSO(2) is enticing because it is simpler and less expensive than other neuromonitoring modalities. This study was performed to compare the efficacy of rSO(2) with electroencephalography (EEG) and median nerve somatosensory evoked potentials (SSEP) in determining when to place a shunt during CEA.MethodsFrom October 2000 to June 2006, 323 CEAs were performed under general anesthesia by six surgeons. Shunting was done selectively on the basis of EEG and SSEP monitoring under the auspices of an intraoperative neurophysiologist. All patients were retrospectively reviewed to see if significant discrepancies existed between EEG/SSEP and rSO(2).ResultsTwenty-four patients (7.4%) showed significant discrepancies. Sixteen patients showed no significant EEG/SSEP changes, but profound changes occurred in rSO(2), and no shunt was placed. In seven patients there was no change in rSO(2) but a profound change occurred in EEG/SSEP, and shunts were placed. In one patient early in the series, the EEG and SSEP were unchanged but the rSO(2) dropped precipitously, and a shunt was placed. In the 299 patients who showed no discrepancies, 285 were not shunted and 14 required a shunt. Two strokes occurred in the entire series (0.6%), none intraoperatively. Shunts were placed in 23 patients (7%). The sensitivity of rSO(2) compared with EEG/SSEP was 68%, and the specificity was 94%. This gave a positive-predictive value of 47% and a negative-predictive value of 98%.ConclusionsRelying on rSO(2) alone for selective shunting is potentially dangerous and might have led to intraoperative ischemic strokes in seven patients and the unnecessary use of shunts in at least 16 patients in this series. The use of rSO(2) adds nothing to the information already provided by EEG and SSEP in determining when to place a shunt during CEA.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.