• Crit Care · Jan 2008

    Effect of a heated humidifier during continuous positive airway pressure delivered by a helmet.

    • Davide Chiumello, Monica Chierichetti, Federica Tallarini, Paola Cozzi, Massimo Cressoni, Federico Polli, Riccardo Colombo, Antonio Castelli, and Luciano Gattinoni.
    • Unità Operativa di Anestesia e Rianimazione, Fondazione IRCCS - 'Ospedale Maggiore Policlinico, Mangiagalli, Regina Elena', via F, Sforza 35, 20122 Milan, Italy. chiumello@libero.it
    • Crit Care. 2008 Jan 1;12(2):R55.

    IntroductionThe helmet may be an effective interface for the delivery of noninvasive positive pressure ventilation. The high internal gas volume of the helmet can act as a 'mixing chamber', in which the humidity of the patient's expired alveolar gases increases the humidity of the dry medical gases, thus avoiding the need for active humidification. We evaluated the temperature and humidity of respiratory gases inside the helmet, with and without a heated humidifier, during continuous positive airway pressure (CPAP) delivered with a helmet.MethodsNine patients with acute respiratory failure (arterial oxygen tension/fractional inspired oxygen ratio 209 +/- 52 mmHg) and 10 healthy individuals were subjected to CPAP. The CPAP was delivered either through a mechanical ventilator or by continuous low (40 l/min) or high flow (80 l/min). Humidity was measured inside the helmet using a capacitive hygrometer. The level of patient comfort was evaluated using a continuous scale.ResultsIn patients with acute respiratory failure, the heated humidifier significantly increased the absolute humidity from 18.4 +/- 5.5 mgH2O/l to 34.1 +/- 2.8 mgH2O/l during ventilator CPAP, from 11.4 +/- 4.8 mgH2O/l to 33.9 +/- 1.9 mgH2O/l during continuous low-flow CPAP, and from 6.4 +/- 1.8 mgH2O/l to 24.2 +/- 5.4 mgH2O/l during continuous high-flow CPAP. Without the heated humidifier, the absolute humidity was significantly higher with ventilator CPAP than with continuous low-flow and high-flow CPAP. The level of comfort was similar for all the three modes of ventilation and with or without the heated humidifier. The findings in healthy individuals were similar to those in the patients with acute respiratory failure.ConclusionThe fresh gas flowing through the helmet with continuous flow CPAP systems limited the possibility to increase the humidity. We suggest that a heated humidifier should be employed with continuous flow CPAP systems.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,694,794 articles already indexed!

We guarantee your privacy. Your email address will not be shared.