-
Paediatric anaesthesia · Oct 2008
Lower cuff pressures improve the seal of pediatric laryngeal mask airways.
- Ana Licina, Neil A Chambers, Bruce Hullett, Thomas O Erb, and Britta S von Ungern-Sternberg.
- Department of Anesthesia, Princess Margaret Hospital for Children, Perth, WA, Australia.
- Paediatr Anaesth. 2008 Oct 1;18(10):952-6.
BackgroundHyperinflation of laryngeal mask airway (LMA) cuffs may be harmful because of the exertion of high pressures on pharyngeal and laryngeal structures. Although cuff manometers may be used to monitor cuff pressure, their use is not routine in many institutions and clinical endpoints are used instead. Furthermore, it is common clinical practice to add air to the cuff in the presence of an air leak to obtain a better seal.MethodsIn a prospective audit, the authors assessed air leakage around pediatric sized LMAs (n = 200) following inflation guided by common clinical endpoints (slight outward movement of the LMA) and then following adjustment of the cuff pressure to the recommended pressure range (<60 cmH(2)O) according to institutional guidelines with the use of a calibrated cuff manometer, directly after induction of anesthesia. Following induction, all children were gently ventilated with pressure control ventilation with 10 cmH(2)O and a positive end-expiratory pressure of 5 cmH(2)O.ResultsFollowing inflation of the cuff guided by clinical endpoints, the median initial cuff pressure (LMA size 1-3) was 92 (size 3) to >120 cmH(2)O (size 1) and the median leakage around the cuff ranged from 0.66 to 1.07 ml x kg(-1). Following cuff pressure adjustment according to the recommended pressure range (<60 cmH(2)O), the leakage decreased significantly to 0.51-0.79 ml x kg(-1) (P = 0.002 for size 1, P < 0.001 for size 1.5-3).ConclusionThe use of clinical endpoints to inflate LMA cuffs is not only associated with significant hyperinflation in the majority of patients but also with an increased leakage around the LMA cuff when compared with adjusted LMA cuff pressures. Therefore, cuff manometers should routinely be used not only to avoid unnecessary hyperinflation but also to improve cuff sealing of LMA in children.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.