    AbstractWe investigated which haemodynamic parameters derived from Nexfin non-invasive continuous arterial blood pressure measurements are optimal to detect controlled volume loss in spontaneously breathing subjects. Haemodynamic monitoring was performed in 40 whole-blood donors. Mean arterial pressure, cardiac index, systemic vascular resistance index and pulse pressure variation were recorded during controlled breathing, and a Valsalva manoeuvre was performed before and after blood donation. Blood donation resulted in a reduction in cardiac index (from 3.96 ± 0.84 l.min(-1) .m(2) to 3.30 ± 0.61 l.min(-1) .m(2) ; p < 0.001), an increase in systemic vascular resistance (from 1811 ± 450 dyn.s.cm(-5) .m(2) to 2137 ± 428 dyn.s.cm(-5) .m(2) ; p < 0.001) and an increase in pulse pressure variation (from 13.4 ± 5.1 to 15.3 ± 5.4%; p = 0.02). The area under the receiver operating characteristic curve to detect volume loss was highest for cardiac index (0.94, 95% CI 0.88-0.99) and systemic vascular resistance (0.90, 95% CI 0.82-0.99). Nexfin is a non-invasive haemodynamic monitor that can feasibly detect volaemic changes in spontaneously breathing subjects.© 2015 The Association of Anaesthetists of Great Britain and Ireland.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…