-
Zhongguo Yi Xue Ke Xue Yuan Xue Bao · Oct 2011
Randomized Controlled Trial[Application of ultrasonic surface location for internal jugular vein catheterization via central approach].
- Yi-Long Zhang, Wei-Dong Mi, De-Jiang Yu, Qiang Fu, and Xue-Xin Feng.
- Anesthesia and Operation Center, PLA General Hospital, Beijing 100853, China.
- Zhongguo Yi Xue Ke Xue Yuan Xue Bao. 2011 Oct 1;33(5):479-84.
ObjectiveTo explore the clinical value of ultrasonic surface localization in internal jugular vein catheterization.MethodsTotally 150 patients with American Society of Anesthesiologists physical status I -III who were planning to receive elective surgeries were randomized into anatomical landmark group, ultrasonic surface positioning group, and ultrasound-guided group using computed random table, with 50 cases in each group. The right internal jugular vein catheterization was performed after tracheal intubation. In the anatomic landmark group, patients were punctured using surface marks through central approach. In ultrasonic surface positioning group and ultrasound-guided group, patients were punctured with ultrasonic localization and guidance through central approach. The relationship between internal jugular vein and carotid artery, the position of the needle into the vein, the success rate of puncture, the change times of puncture point, and the complications were recorded.ResultsUltrasound scan revealed that the relationship between the right internal jugular vein and the right common carotid artery could be divided into three types: parallel (12.7%), partial overlapping (69.3%), and complete overlapping (18.0%). The average "safety distance" of jugular vein puncture was (1.15 +/- 0.47) cm. The success rate of the first puncture attempt in ultrasonic surface positioning group and ultrasound-guided group were 78.0% and 82.0%, respectively, which was significantly higher than that in anatomic landmark group (22.0%) (P < 0.05), whereas the complication incidence in anatomic landmark group (12.0%) were significantly higher than those in ultrasonic surface positioning group (0) and ultrasound-guided group (0) (P < 0.05).ConclusionsUltrasonic surface positioning applied during internal jugular vein catheterization is helpful to reveal the inner diameters as well as the origin and course of arteries and veins in the puncture and identify the abnormalities as early as possible. As a simple support technique for internal jugular vein puncture, it is suitable for clinical application.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.