• J. Am. Coll. Surg. · Jul 2009

    Intensivist use of hand-carried ultrasonography to measure IVC collapsibility in estimating intravascular volume status: correlations with CVP.

    • S Peter Stawicki, Benjamin M Braslow, Nova L Panebianco, James N Kirkpatrick, Vicente H Gracias, Geoffrey E Hayden, and Anthony J Dean.
    • Department of Surgery, Division of Traumatology and Surgical Critical Care, University of Pennsylvania School of Medicine, Philadelphia, PA, USA.
    • J. Am. Coll. Surg. 2009 Jul 1;209(1):55-61.

    BackgroundVolume status assessment is an important aspect of patient management in the surgical intensive care unit (SICU). Echocardiologist-performed measurement of IVC collapsibility index (IVC-CI) provides useful information about filling pressures, but is limited by its portability, cost, and availability. Intensivist-performed bedside ultrasonography (INBU) examinations have the potential to overcome these impediments. We used INBU to evaluate hemodynamic status of SICU patients, focusing on correlations between IVC-CI and CVP.Study DesignProspective evaluation of hemodynamic status was conducted on a convenience sample of SICU patients with a brief (3 to 10 minutes) INBU examination. INBU examinations were performed by noncardiologists after 3 hours of didactics in interpreting and acquiring two-dimensional and M-mode images, and > or =25 proctored examinations. IVC-CI measurements were compared with invasive CVP values.ResultsOf 124 enrolled patients, 101 had CVP catheters (55 men, mean age 58.3 years, 44.6% intubated). Of these, 18 patients had uninterpretable INBU examinations, leaving 83 patients with both CVP monitoring devices and INBU IVC evaluations. Patients in three IVC-CI ranges (<0.20, 0.20 to 0.60, and >0.60) demonstrated significant decrease in mean CVP as IVC-CI increased (p = 0.023). Although <5% of patients with IVC-CI <0.20 had CVP <7 mmHg, >40% of this group had a CVP >12 mmHg. Conversely, >60% of patients with IVC-CI >0.6 had CVP <7 mmHg.ConclusionsMeasurements of IVC-CI by INBU can provide a useful guide to noninvasive volume status assessment in SICU patients. IVC-CI appears to correlate best with CVP in the setting of low (<0.20) and high (>0.60) collapsibility ranges. Additional studies are needed to confirm and expand on findings of this study.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…