• Int J Crit Illn Inj Sci · Apr 2015

    Dynamic behavior of venous collapsibility and central venous pressure during standardized crystalloid bolus: A prospective, observational, pilot study.

    • Stanislaw P Stawicki, Alistair Kent, Prabhav Patil, Christian Jones, Jill C Stoltzfus, Amar Vira, Nicholas Kelly, Andrew N Springer, Daniel Vazquez, David C Evans, Thomas J Papadimos, and David P Bahner.
    • Department of Research and Innovation, St Luke's University Health Network, Bethlehem, Pennsylvania, United States.
    • Int J Crit Illn Inj Sci. 2015 Apr 1;5(2):80-4.

    IntroductionMeasurement of intravascular volume status is an ongoing challenge for physicians in the surgical intensive care unit (SICU). Most surrogates for volume status, including central venous pressure (CVP) and pulmonary artery wedge pressure, require invasive lines associated with a number of potential complications. Sonographic assessment of the collapsibility of the inferior vena cava (IVC) has been described as a noninvasive method for determining volume status. The purpose of this study was to analyze the dynamic response in IVC collapsibility index (IVC-CI) to changes in CVP in SICU patients receiving fluid boluses for volume resuscitation.Materials And MethodsA prospective pilot study was conducted on a sample of SICU patients who met clinical indications for intravenous (IV) fluid bolus and who had preexisting central venous access. Boluses were standardized to crystalloid administration of either 500 mL over 30 min or 1,000 mL over 60 min, as clinically indicated. Concurrent measurements of venous CI (VCI) and CVP were conducted right before initiation of IV bolus (i.e. time 0) and then at 30 and 60 min (as applicable) after bolus initiation. Patient demographics, ventilatory parameters, and vital sign assessments were recorded, with descriptive outcomes reported due to the limited sample size.ResultsTwenty patients received a total of 24 IV fluid boluses. There were five recorded 500 mL boluses given over 30 min and 19 recorded 1,000 mL boluses given over 60 min. Mean (median) CVP measured at 0, 30, and 60 minutes post-bolus were 6.04 ± 3.32 (6.5), 9.00 ± 3.41 (8.0), and 11.1 ± 3.91 (12.0) mmHg, respectively. Mean (median) IVC-CI values at 0, 30, and 60 min were 44.4 ± 25.2 (36.5), 26.5 ± 22.8 (15.6), and 25.2 ± 21.2 (14.8), respectively.ConclusionsObservable changes in both VCI and CVP are apparent during an infusion of a standardized fluid bolus. Dynamic changes in VCI as a measurement of responsiveness to fluid bolus are inversely related to changes seen in CVP. Moreover, an IV bolus tends to produce an early response in VCI, while the CVP response is more gradual. Given the noninvasive nature of the measurement technique, VCI shows promise as a method of dynamically measuring patient response to fluid resuscitation. Further studies with larger sample sizes are warranted.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.