• Ann Vasc Surg · Aug 2011

    Randomized Controlled Trial Multicenter Study Comparative Study

    Use of fibrin sealant as a hemostatic agent in expanded polytetrafluoroethylene graft placement surgery.

    • Sibu P Saha, Satish Muluk, Worthington Schenk, Sandra G Burks, Ani Grigorian, Bettina Ploder, Isabella Presch, Borislava G Pavlova, and Edith Hantak.
    • Division of Cardiovascular and Thoracic Surgery, Department of Surgery, University of Kentucky, Lexington, KY, USA.
    • Ann Vasc Surg. 2011 Aug 1;25(6):813-22.

    BackgroundThe low thrombogenicity, porosity, and limited elasticity of expanded polytetrafluoroethylene (ePTFE) vascular grafts, although beneficial, may exacerbate the problem of suture-line bleeding at vascular anastomoses and consequently lead to increased operating times. The overall objective of this prospective, randomized, controlled, subject-blinded, multicenter phase 2 study was to evaluate the efficacy and safety of a fibrin sealant containing 500 IU/mL thrombin and synthetic aprotinin (FS; marketed in the United States under the name TISSEEL) for hemostasis in subjects undergoing vascular surgery and receiving prosthetic ePTFE vascular grafts.MethodsFS was compared with manual compression with surgical gauze pads, a standard of care for hemostasis in vascular surgery. Two FS polymerization/setting times (60 and 120 seconds) were investigated to evaluate influence on the efficacy results. Patients undergoing ePTFE graft placement surgery (N = 73) who experienced bleeding that required treatment after surgical hemostasis were randomized to be treated with FS with clamps opened at 60 seconds (FS-60; N = 26), with FS with clamps opened at 120 seconds (FS-120; N = 24), or with manual compression with surgical gauze pads (control; N = 23). The proportion of subjects achieving hemostasis at 4 minutes (primary endpoint) as well as at 6 and 10 minutes (secondary endpoints) in the three treatment groups was analyzed using logistic regression analysis, taking into account gender, age, type of intervention, severity of bleeding, systolic blood pressure, diastolic blood pressure, heparin coating of the ePTFE graft, and platelet inhibitors.ResultsThere were substantial differences in the proportion of subjects who achieved hemostasis at the study suture line at 4 minutes from treatment application between FS-120 (62.5%) and control (34.8%) groups (a 79.6% relative improvement). Logistic regression analyses found a statistically significant treatment effect at the 10% level in the odds ratio (OR) of achieving hemostasis at 4 minutes between the FS-120 and control groups (OR = 3.98, p = 0.0991). Furthermore, it has been shown that the perioperative administration of platelet inhibitors significantly influences (OR = 3.89, p = 0.0607) hemostasis rates at the primary endpoint. No statistically significant treatment effects were found for the other factors. Logistic regression analyses performed on the secondary endpoints demonstrated a significant treatment effect of achieving hemostasis at 6 minutes (OR = 9.92, p = 0.0225) and at 10 minutes (OR = 6.70, p = 0.0708) between the FS-120 and control groups. Statistically significant effects in the logistic regression analyses were found at the 10% level in the OR of achieving hemostasis at 6 and 10 minutes, respectively, for the following factors: FS-120 versus control group (OR = 9.92; p = 0.0225 and OR = 6.70; p = 0.0708, respectively), type of intervention (OR = 0.3; p = 0.0775 and OR = 0.25; p = 0.0402, respectively), and heparin coating of the ePTFE prosthesis (OR = 4.83; p = 0.0413 and OR = 3.65; p = 0.0911, respectively). FS was safe and well-tolerated, as indicated by the lack of any related serious adverse events.ConclusionThe findings from this phase 2 study support the strong safety profile of FS and suggest that it is an efficacious hemostatic agent in ePTFE graft placement surgery, as well as a useful tool in peripheral vascular surgery applications.Copyright © 2011 Annals of Vascular Surgery Inc. Published by Elsevier Inc. All rights reserved.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,694,794 articles already indexed!

We guarantee your privacy. Your email address will not be shared.