• J. Vasc. Surg. · Oct 2005

    Comparative Study

    Stenosis detection in failing hemodialysis access fistulas and grafts: comparison of color Doppler ultrasonography, contrast-enhanced magnetic resonance angiography, and digital subtraction angiography.

    • Cornelis Doelman, Lucien E M Duijm, Ylian S Liem, Clemence L Froger, Alexander V Tielbeek, Astrid B Donkers-van Rossum, Philippe W M Cuypers, Petra Douwes-Draaijer, Jaap Buth, and Harrie C M van den Bosch.
    • Department of Radiology, Catharina Hospital, Eindhoven, The Netherlands.
    • J. Vasc. Surg. 2005 Oct 1;42(4):739-46.

    ObjectiveSeveral imaging modalities are available for the evaluation of dysfunctional hemodialysis shunts. Color Doppler ultrasonography (CDUS) and digital subtraction angiography (DSA) are most widely used for the detection of access stenoses, and contrast-enhanced magnetic resonance angiography (CE-MRA) of shunts has recently been introduced. To date, no study has compared the value of these three modalities for stenosis detection in dysfunctional shunts. We prospectively compared CDUS and CE-MRA with DSA for the detection of significant (> or = 50%) stenoses in failing dialysis accesses, and we determined whether the interventionalist would benefit from CDUS performed before DSA and endovascular intervention.MethodsCDUS, CE-MRA, and DSA were performed of 49 dysfunctional hemodialysis arteriovenous fistulas and 32 grafts. The vascular tree of the accesses was divided into three to eight segments depending on the access type (arteriovenous fistula or arteriovenous graft) and the length of venous outflow. CDUS was performed and assessed by a vascular technician, whereas CE-MRA and DSA were interpreted by two magnetic resonance radiologists and two interventional radiologists, respectively. All readers were blinded to information from each other and from other studies. DSA was used as reference standard for stenosis detection.ResultsDSA detected 111 significant (> or = 50%) stenoses in 433 vascular segments. Sensitivity and specificity of CDUS for the detection of significant stenosed vessel segments were 91% (95% CI, 84%-95%) and 97% (95% CI, 94%-98%), respectively. We found a positive predictive value of 91% (95% CI, 84%-95%) and a negative predictive value of 97% (95% CI, 94%-98%). The sensitivity, specificity, positive predictive value, and negative predictive value of MRA were 96% (95% CI, 90%-98%), 98% (95% CI, 96%-99%), 94% (95% CI, 88%-97%), and 98% (95% CI, 96%-99%), respectively. CDUS and CE-MRA depicted respectively three and four significant stenoses in six nondiagnostic DSA segments. The interventionalist would have chosen an alternative cannulation site in 38% of patients if the CDUS results had been available.ConclusionsWe suggest that CDUS be used as initial imaging modality of dysfunctional shunts, but complete access should be depicted at DSA and angioplasty to detect all significant stenoses eligible for intervention. CE-MRA should be considered only if DSA is inconclusive.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.