• Journal of critical care · Aug 2013

    Correlation of oxygen saturation as measured by pulse oximetry/fraction of inspired oxygen ratio with Pao2/fraction of inspired oxygen ratio in a heterogeneous sample of critically ill children.

    • Juan Mayordomo-Colunga, Corsino Rey, Alberto Medina, Carlos Lobete, Andrés Concha, and Sergio Menéndez.
    • Pediatric Intensive Care Unit, Hospital Universitario Central de Asturias, University of Oviedo, Oviedo, Spain. carloslobete@hotmail.com
    • J Crit Care. 2013 Aug 1;28(4):538.e1-7.

    PurposeOxygen saturation as measured by pulse oximetry (Spo2)/fraction of inspired oxygen (Fio2) (SF) ratio has demonstrated to be an adequate marker for lung disease severity in children under mechanical ventilation. We sought to validate the utility of SF ratio in a population of critically ill children under mechanical ventilation, noninvasive ventilation support, and breathing spontaneously.Materials And MethodsA retrospective database study was conducted in a pediatric intensive care unit of a university hospital. Children with Spo2 less than or equal to 97% and an indwelling arterial catheter were included. Simultaneous blood gas and pulse oximetry were collected in a database. Derivation and validation data sets were generated, and a linear mixed modeling was used to derive predictive equations. Model performance and fit were evaluated using the validation data set.ResultsThree thousand two hundred forty-eight blood gas and Spo2 values from 298 patients were included. 1/SF ratio had a strong linear association with 1/Pao2/Fio2 (PF) ratio in both derivation and validation data sets, given by the equation 1/SF = 0.00164 + 0.521/PF (derivation). Oxygen saturation as measured by pulse oximetry/Fio2 values for PF criteria of 100, 200, and 300 were 146 (95% confidence interval [CI], 142-150), 236 (95% CI, 228-244), and 296 (95% CI, 285-308). Areas under receiver operating characteristic curves for diagnosis of PF ratio less than 100, 200, and 300 with the SF ratio were 0.978, 0.952, and 0.951, respectively, in the validation data set.ConclusionsOxygen saturation as measured by pulse oximetry/Fio2 ratio is an adequate noninvasive surrogate marker for PF ratio. Oxygen saturation as measured by pulse oximetry/Fio2 ratio may be an ideal noninvasive marker for patients with acute hypoxemic respiratory failure.Copyright © 2013 Elsevier Inc. All rights reserved.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…