- S L Vrancken, W P de Boode, J C Hopman, M G Looijen-Salamon, K D Liem, and A F van Heijst.
- Department of Paediatrics-Neonatology, Radboud University Nijmegen Medical Centre, Internal Postal Code 804, PO Box 9101, 6500 HB Nijmegen, The Netherlands. s.vrancken@cukz.umcn.nl
- Br J Anaesth. 2012 Dec 1;109(6):870-8.
BackgroundTranspulmonary ultrasound dilution (TPUD) is a promising method for cardiac output (CO) measurement in severely ill neonates. The incidence of lung injury in this population is high, which might influence CO measurement using TPUD because of altered lung perfusion. We evaluated the influence of lung injury on the accuracy and precision of CO measurement using TPUD in an animal model.MethodsIn nine neonatal lambs, central venous and arterial catheters were inserted and connected to the TPUD monitor. Repeated lavages with warmed isotonic saline were performed to gradually induce lung injury. CO measurements with TPUD (COtpud) were compared with those obtained by an ultrasonic transit-time flow probe around the main pulmonary artery (COufp). An increase in oxygenation index was used as an indicator of induced lung injury during the experiment. Post-mortem lung injury was confirmed by histopathological examination.ResultsFifty-five sessions of three paired CO measurements were analysed. The mean COufp was 1.53 litre min(-1) (range 0.66-2.35 litre min(-1)), and the mean COtpud was 1.65 litre min(-1) (range 0.78-2.91 litre min(-1)). The mean bias (standard deviation) between the two methods was 0.13 (0.15) litre min(-1) with limits of agreement of ±0.29 litre min(-1). The overall percentage error was 19.1%. The accuracy and precision did not change significantly during progressive lung injury. Histopathological severity scores were consistent with heterogeneous lung injury. The capability to track changes in CO using TPUD was moderate to good.ConclusionsThe accuracy and precision of CO measurement using TPUD is not influenced in the presence of heterogeneous lung injury in an animal model.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.