    Femoral anteversion in children with cerebral palsy. Assessment with two and three-dimensional computed tomography scans.

    • Jon R Davids, Amanda D Marshall, Edward R Blocker, Steven L Frick, Dawn W Blackhurst, and Edward Skewes.
    • Shriners Hospital for Children, Greenville, South Carolina 29605, USA. jdavids@shrinenet.org
    • J Bone Joint Surg Am. 2003 Mar 1;85-A(3):481-8.

    BackgroundAssessment of femoral anteversion in children with cerebral palsy with two or three-dimensional computed tomography scans may be limited by both positional and anatomic variables. Three-dimensional computed tomography techniques are considered to be more accurate than two-dimensional imaging when the femur is not optimally positioned in the gantry or when the neck-shaft angle is increased.MethodsComputed tomography scanning was performed on a series of nine model femora with anteversion ranging from 20 degrees to 60 degrees and neck-shaft angles ranging from 120 degrees to 160 degrees. Each femoral model was scanned in two holding devices, the first of which held the femur in optimal alignment (normal model) and the second of which held the femur in flexion, adduction, and internal rotation (cerebral palsy model) relative to the gantry. Femoral anteversion was calculated for each model from two and three-dimensional computed tomography scans by four examiners on two separate occasions. The intraobserver and interobserver reliability, the accuracy, and the effect of increasing the neck-shaft angle on the accuracy of the measurements made on the two and three-dimensional scans of the normal and cerebral palsy models were then examined.ResultsThe mean differences in the measurements of femoral anteversion made by the same examiner (intraobserver reliability) were <2 degrees for the two-dimensional scans of the normal and cerebral palsy models and the three-dimensional scans of the normal models, and the mean difference was <4 degrees for the three-dimensional scans of the cerebral palsy models. The mean differences among examiners (interobserver reliability) were <3 degrees for the two-dimensional scans of the normal and cerebral palsy models and the three-dimensional scans of the normal models, and the mean difference was <6 degrees for the three-dimensional scans of the cerebral palsy models. The accuracy of the assessments of femoral anteversion of the normally aligned models was comparable between the two and three-dimensional scans. However, the three-dimensional assessment was significantly more accurate than the two-dimensional assessment for measurement of anteversion of the cerebral palsy models (p = 0.003). Accuracy within 5 degrees was comparable between the two and three-dimensional scans for measurement of the normally aligned models, with 86% of the two-dimensional measurements and 78% of the three-dimensional measurements falling within 5 degrees of the actual measurements. However, the accuracy within 5 degrees was significantly compromised when the models were placed in cerebral palsy alignment. Only 3% of the two-dimensional measurements and 14% of the three-dimensional measurements fell within 5 degrees of the actual measurements, with three-dimensional assessment being significantly better than two-dimensional assessment (p = 0.006). Increasing the neck-shaft angle did not significantly compromise the accuracy of measurement of femoral anteversion with either the two-dimensional or the three-dimensional technique (p > 0.05 for all comparisons).ConclusionsWhen adequate alignment of the femur in the computed tomography scanner was possible, a simple two-dimensional technique exhibited excellent intraobserver and interobserver reliability and clinically acceptable accuracy within the relevant ranges of anatomic variability tested (neck-shaft angles of 120 degrees to 160 degrees and femoral anteversion of 20 degrees to 60 degrees). When optimal alignment of the femur in the scanner was not possible, neither two-dimensional nor three-dimensional techniques exhibited clinically acceptable accuracy for the measurement of femoral anteversion.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.