-
Observational Study
Intraosseous access in the military operational setting.
- J Vassallo, S Horne, and J E Smith.
- J R Nav Med Serv. 2014 Jan 1;100(1):34-7.
IntroductionIn an operational military environment, circulatory access can prove difficult for a variety of reasons including profound hypovolaemia, and limited first responder experience. With many injuries that cause catastrophic haemorrhage, such as traumatic limb amputations, circulatory access is needed as quickly as possible. Since 2006, the Defence Medical Services have been using the EZ-IO and FAST1 devices as a means of obtaining circulatory access.MethodsA prospective observational study was conducted between March and July 2011 at the Emergency Department, Camp Bastion, Afghanistan. All patients with an intraosseous device had data recorded that included if the device successfully flushed (functionality) and if any problems were encountered.Results117 patients presented with a total of 195 devices: 149 were EZ-IO (76%) and 46 were FAST1 (24%). Functionality was recorded for 111 (57%), with 17 failing to function, yielding an overall success rate of 84.7%. Device failure was observed to be more prevalent in the humerus; inability to flush the device was the leading cause, followed by mechanical failure. There were 2 complications, device breaking on removal being the reason for both.ConclusionsThe devices in the study were tested for a period of time following insertion (median 32 minutes), and still the success rates mirror those found in the literature. Observed differences between sites were not found to be significant with confidence intervals overlapping. Further work is proposed to investigate the long-term complications of intraosseous devices.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.