-
Acta ophthalmologica · Sep 2011
Dependence of the optic nerve sheath diameter on acutely applied subarachnoidal pressure - an experimental ultrasound study.
- Hans-Christian Hansen, Wolf Lagrèze, Oswald Krueger, and Knut Helmke.
- Department of Neurology & Psychiatry, Friedrich-Ebert-Hospital Neumuenster/University of Hamburg, Hamburg, Germany. hc.hansen@fek.de
- Acta Ophthalmol. 2011 Sep 1;89(6):e528-32.
PurposeTo determine the distensibility and elastic characteristics of the optic nerve sheath for development of a basic understanding of ultrasound studies aimed to measure optic nerve sheath diameter (ONSD) for detection of acutely elevated intracranial pressure (ICP).MethodsIsolated human optic nerves preparations obtained from autopsies were submitted to predefined pressure alterations, and consecutive changes in ONSD were measured by B-scan ultrasound under defined conditions.ResultsFollowing submission to pressure, the diameter of the nerve sheath increased up to 140% of its baseline value. The increase (mean 1.97 mm, SD 0.52 mm) corresponded to the magnitude of pressure steps measured in the perineural subarachnoidal space (SAS). Similarly, the ONSD declined in each of the preparations within a few minutes after the optic nerve was decompressed. However, it did not reach its baseline value again when pressure loads of 45-55 mmHg or more had been applied.ConclusionsThe elasticity of the anterior sheath of the optic nerve is sufficient for the detection of pressure changes in the SAS especially for upward pressure steps. This is basically important for the application of clinical monitoring of the sheath diameter to facilitate the identification of patients with elevated ICP non-invasively (screening). However, further implementation of this procedure in neurointensive care and emergency medicine has to consider that the sheath diameter reversibility may be impaired after episodes of prolonged intracranial hypertension and a model for hysteresis is proposed.© 2011 The Authors. Acta Ophthalmologica © 2011 Acta Ophthalmologica Scandinavica Foundation.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.