• J Clin Monit · Jul 1996

    Evaluation of a regional oxygen saturation catheter for monitoring SjvO2 in head injured patients.

    • A M Ritter, S P Gopinath, C Contant, R K Narayan, and C S Robertson.
    • Department of Neurosurgery, Baylor College of Medicine, Houston, Texas 77030, USA.
    • J Clin Monit. 1996 Jul 1;12(4):285-91.

    ObjectivesMonitoring jugular venous oxygen saturation (SjvO2) has been useful for the early identification and treatment of cerebral ischemia in patients with severe head injury. However, the catheters that have been used for this purpose have not performed optimally. The purpose of this study was to evaluate the performance of a new regional oxygen saturation catheter for monitoring SjvO2.MethodsEighteen regional oxygen saturation catheters, 4-Fr in diameter (Baxter Healthcare Corporation, Edward Critical Care), were used in this study. Each catheter was inserted percutaneously into the dominant jugular vein and the catheter's tip position in the jugular bulb was verified by radiograph. The catheter was calibrated in vitro prior to insertion using the optic calibrator provided by the manufacturer. The catheter was recalibrated every 8 to 12 hours by comparing the oxygen saturation value from the catheter with that measured by a co-oximeter in a blood sample drawn through the catheter.ResultsIn vitro calibration using the optic calibrator was not always successful. Five catheters could not be calibrated. The remaining 13 catheters could all be calibrated, but only 9 provided a value that was within 4% of the oxygen saturation derived from the blood sample. After the first in vivo calibration, the correlation between the catheter and the blood sample values was improved. A total of 196 comparisons were made. The median, 25th, and 75th quartile differences between the catheter and the blood sample measurement of SjvO2 were 0.00, -1.15, and 1.25%, respectively. Using longitudinal data regression, the overall slope of the regression between the catheter and blood values was 0.997 (p = 0.001).ConclusionsThe new regional oxygen saturation catheter provided reliable measurement of SjvO2 83% of the time when the signal quality index was < or = 3, and may be useful for continuous monitoring of SjvO2.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.