    BackgroundSpinal anesthesia for cesarean delivery may cause severe maternal hypotension and a decrease in cardiac output. Compared to assessment of cardiac output via a pulmonary artery catheter, the FloTrac/Vigileo system may offer a less invasive technique. The aim of this study was to evaluate cardiac output and other hemodynamic measurements made using the FloTrac/Vigileo system in patients undergoing spinal anesthesia for elective cesarean section.MethodsA prospective study enrolling 10 healthy pregnant women was performed. Hemodynamic parameters were continuously obtained at 15 main points: admission to surgery (two baseline measurements), after preload, after spinal anesthesia administration and 4 time points thereafter (4, 6, 8 and 10 min after anesthesia), at skin and uterine incision, newborn and placental delivery, oxytocin administration, end of surgery, and recovery from anesthesia. Hemodynamic therapy was guided by mean arterial pressure, and vasopressors were used as appropriate to maintain baseline values. A repeated measures ANOVA was used for data analysis.ResultsThere was a significant increase in heart rate and a decrease of stroke volume and stroke volume index up to 10 min after spinal anesthesia (P < 0.01). Importantly, stroke volume variation increased immediately after newborn delivery (P < 0.001) and returned to basal values at the end of surgery. Further hemodynamic parameters showed no significant changes over time.Discussion And ConclusionsNo significant hemodynamic effects, except for heart rate and stroke volume changes, were observed in pregnant women managed with preload and vasopressors when undergoing elective cesarean section and spinal anesthesia.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.