J. Am. Coll. Cardiol. · Nov 2002
Comparative StudyComparative value of Doppler echocardiography and B-type natriuretic peptide assay in the etiologic diagnosis of acute dyspnea.
- Damien Logeart, Carole Saudubray, Pascale Beyne, Gabriel Thabut, Pierre-Vladimir Ennezat, Christophe Chavelas, Caroline Zanker, Erik Bouvier, and Alain Cohen Solal.
- Service de Cardiologie, Hôpital Beaujon, Assistance Publique-Hôpitaux de Paris, 100 Boulevard du Gal Leclerc, 92110 Clichy, France. damien.logeart@bjn.ap-hop-paris.fr
- J. Am. Coll. Cardiol. 2002 Nov 20;40(10):1794-800.
ObjectivesWe compared the accuracy of B-type natriuretic peptide (BNP) assay with Doppler echocardiography for the diagnosis of decompensated congestive left-heart failure (CHF) in patients with acute dyspnea.BackgroundBoth BNP and Doppler echocardiography have been described as relevant diagnostic tests for heart failure.MethodsOne hundred sixty-three consecutive patients with severe dyspnea underwent BNP assay and Doppler echocardiogram on admission. The accuracy of the two methods for etiologic diagnosis was compared on the basis of the final diagnoses established by physicians who were blinded to the BNP and Doppler findings.ResultsThe final etiologic diagnosis was CHF in 115 patients. Twenty-four patients (15%) were misdiagnosed at admission. The BNP concentration was 1,022 +/- 742 pg/ml in the CHF subgroup and 187 +/- 158 pg/ml in the other patients (p < 0.01). A BNP cutoff of 300 pg/ml correctly classified 88% of the patients (odds ratio [OR] 85 [19 to 376], p < 0.0001), but a high negative predictive value (90%) was only obtained when the cutoff was lowered to 80 pg/ml. The etiologic value of BNP was low in patients with values between 80 and 300 pg/ml (OR 1.85 [0.4 to 7.8], p = 0.4) and also in patients who were studied very soon after onset of acute dyspnea. Among the 138 patients with assessable Doppler findings, a "restrictive" mitral inflow pattern had a diagnostic accuracy for CHF of 91% (OR 482 [77 to 3,011], p < 0.0001), regardless of the BNP level.ConclusionsBedside BNP measurement and Doppler echocardiography are both useful for establishing the cause of acute dyspnea. However, Doppler analysis of the mitral inflow pattern was more accurate, particularly in patients with intermediate BNP levels or "flash" pulmonary edema.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.