-
J. Heart Lung Transplant. · Nov 1999
Multicenter Study Comparative Study Clinical TrialComparison of functional capacity in patients with end-stage heart failure following implantation of a left ventricular assist device versus heart transplantation: results of the experience with left ventricular assist device with exercise trial.
- B E Jaski, R J Lingle, J Kim, K R Branch, R Goldsmith, M R Johnson, J R Lahpor, T B Icenogle, I Piña, R Adamson, L K Favrot, and W P Dembitsky.
- San Diego Cardiac Center, CA 92123, USA.
- J. Heart Lung Transplant. 1999 Nov 1;18(11):1031-40.
BackgroundUse of a permanent left ventricular assist device (LVAD) has been proposed as an alternate treatment of patients with end-stage heart failure. The purpose of this study was to compare the functional capacity of patients following implantation of a LVAD vs heart transplant (HTx).MethodsEighteen patients from 6 centers who received an intracorporeal LVAD as a bridge to HTx underwent treadmill testing 1 to 3 months post-LVAD and again post-HTx. Baseline and peak measurements, including oxygen consumption, blood pressures, and respiratory rate were made during each treadmill test.ResultsPeak oxygen consumption was 14.5+/-3.9 ml/kg/minute post-LVAD and 17.5+/-5.0 ml/kg/minute post-HTx (p < .005). The percentage of the predicted peak oxygen consumption based on gender, weight, and age was 39.5%+/-5.5% post-LVAD and 47.7%+/-10.9% post-HTx (p < .005). Exercise duration was lower post-LVAD than post-HTx (10.3+/-4.2 minute vs 12.5+/-5.4 minute, p < .05). After LVAD implantation, peak total oxygen consumption correlated with peak LVAD rate and output. Eight patients reached an LVAD rate of 120 beats per minute (bpm) before the conclusion of exercise, the maximum rate for the outpatient electric device. The peak respiratory exchange ratio post-LVAD was 1.15+/-0.22 and post-HTx was 1.15+/-0.18, consistent with a good effort in both groups.ConclusionsPatients demonstrated a lower functional capacity post-LVAD than post-HTx. For some patients functional capacity post-LVAD may be improved by a higher maximum LVAD rate and output.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.